i-on Range
Installer Menu Options
Page 63
Type:
(nn=shortcut)
Active when:
Assign to
Partitions?
RF Low Battery
(08)
A wirefree detector reports a low battery.
The output remains active until all
detectors stop reporting low batteries.
Yes
RF Supervision
(09)
There is a supervision failure on any radio
zone. The output remains active until all
supervision failures are reset.
Yes
RF Jamming
(10)
The control unit detects jamming. The
output remains on until all jamming
disappears.
No
RF Fault (11)
There are any of the following faults: RF
Low Battery, RF supervision, RF jamming.
Yes
A/C Fail (12)
Either mains power is absent, OR a zone of
type ―External PSU A/C Fail‖ has been
triggered. The control unit deactivates the
output if a user keys in a valid access code
after mains power has been restored.
The time at which the control unit operates
an A/C Fail output varies as follows:
a) If EITHER mains is present at the
control unit OR has been absent for more
than 10s then the control unit activates the
output.
b) If mains fails at the control unit at the
same time as an external PSU triggers the
External PSU A/C Fail zone input (+/- 10s)
then the control unit waits for the time
programmed in
System Options – Mains Fail
Delay
(see page 95). If control unit mains
is still absent at the end of that time then
the control unit operates the A/C Fail
output.
No
Battery Fault
(13)
The control unit detects a fault with its
backup battery, OR a zone of type
―External PSU Battery Fault‖ has been
triggered. If the alert was caused by an
―External PSU Battery Fault‖ zone then the
control unit deactivates the output when
the zone has been restored and a user has
acknowledges the fault by entering a valid
access code.
If the alert was caused by a fault with the
control unit‘s backup battery then the
control unit deactivates the output when it
detects a good battery and a user
acknowledges the alert.
No