Installer Menu Options
i-on Range
Page 86
Siren on
Unconfirm the control unit operates the siren for all alarms (and overrides
any Siren Delay).
Confirm
When the system is set the control unit does not activate the
siren(s) until a confirmed alarm occurs.
Note: The control unit will not allow you to select “Siren on - Unconfirm” at the
same time as “Sounder on - Confirm”.
Siren Delay and DD243/BS8243
The Sounder On and Siren On options are both affected by the Siren Time and
Siren Delay (see page 75), as follows:
Sounder On Unconfirm/Siren On Unconfirm
Unconfirmed alarm: internal sounders and sirens start immediately and run for
the programmed siren time (see page 75).
Confirmed alarm: the control unit restarts the sirens and internal sounders,
which run for the full programmed siren time (even if that had expired earlier).
Sounder On Unconfirm/Siren On Confirm
Unconfirmed alarm: the internal sounders start immediately and run for the
programmed siren time.
Confirmed alarm: the control unit waits for any programmed siren delay (see
page 75) and then starts both the internal sounders and the external sirens.
These both run for the programmed siren time.
Sounder On Confirmed/Siren On Confirmed
Unconfirmed alarm: No sounders or sirens.
Confirmed alarm: Control unit waits for Siren Delay, and then starts both
internal sounders and external sirens. Both sirens and sounders run for the full
siren time.
Unconfirmed Reset
If you select either ―DD243‖ or ―BS8243‖ for Confirmation Mode then this
option overrides
System Options - User Reset – Zone Alarms
(see page 82). You
may then use the options below:
User
The user can reset after an unconfirmed alarm.
Installer
The user cannot reset after an unconfirmed alarm, the installer
must do it.
Notes:
1.
If a user causes an alarm which would require Installer reset then they
have a time to abort the alarm, which they can then reset themselves.
The time allowed for aborting the alarm can be set by the Abort Timer,
see page 93.
2.
These options apply to intruder alarms only and not to HUAs.