Before you begin, install and configure your chassis and controller.

This document explains how to install, configure, and test the NI PXIe-5698 (NI 5698). The
NI 5698 is an RF preamplifier module designed to work with the NI 5668R vector signal
analyzer. The NI 5698 also functions as a stand-alone preamplifier. The NI 5698 ships with the
NI-RFSA instrument driver, which you use to program the device.

To access NI 5698 documentation, navigate to 

Start

»

All Programs

»

National Instruments

»

NI-RFSA

»

Documentation

.

Caution

 

The protection provided by this product may be impaired if it is used in a

manner not described in this document.

Hot Surface

 

If the NI 5698 has been in use, it may exceed safe handling

temperatures and cause burns. Allow the NI 5698 to cool before removing it from
the chassis.

Contents

Electromagnetic Compatibility Guidelines...............................................................................2
Verifying the System Requirements..........................................................................................2
Unpacking the Kit..................................................................................................................... 2

Verifying the Kit Contents................................................................................................ 3

Preparing the Environment....................................................................................................... 3
Installing the Software.............................................................................................................. 4
Installing the NI 5698............................................................................................................... 4

Direct Connections to the NI 5698................................................................................... 6
Connecting to the NI 5668R............................................................................................. 6
NI 5698 Front Panel..........................................................................................................8

Configuring the NI 5698 in MAX.............................................................................................9
Troubleshooting...................................................................................................................... 10

Why Is the ACCESS LED Off When the Chassis Is On?...............................................11
What Should I Do if the NI 5698 Doesn't Appear in MAX?.......................................... 11
What Should I Do if the Module Fails the Self-Test?..................................................... 11

Where to Go Next................................................................................................................... 12
Worldwide Support and Services............................................................................................ 12

Содержание PXIe-5698

Страница 1: ...t may be impaired if it is used in a manner not described in this document Hot Surface If the NI 5698 has been in use it may exceed safe handling temperatures and cause burns Allow the NI 5698 to cool...

Страница 2: ...ry rules Caution To ensure the specified EMC performance operate this product only with shielded cables and accessories Caution To ensure the specified EMC performance the length of all I O cables mus...

Страница 3: ...river Software DVD 6 NI PXIe 5698 Getting Started Guide This Document 7 Read Me First Safety and Electromagnetic Compatibility 8 Maintain Forced Air Cooling Note to Users Preparing the Environment Ens...

Страница 4: ...ion Accept the prompts to complete the installation 4 When the installer completes select Restart in the dialog box that prompts you to restart shut down or restart later Installing the NI 5698 Cautio...

Страница 5: ...p and bottom of the chassis Slide the device into the slot until it is fully inserted Figure 2 Module Installation 2 3 NI PXIe 1075 1 1 Chassis 2 Hardware Module 3 Ejector Handle in Downward Unlatched...

Страница 6: ...devices are maintained in a static free environment If you are using an active device such as a preamplifier or switch routed to the NI 5698 RF IN connector ensure that the device cannot generate sign...

Страница 7: ...LL performance and may cause insertion loss Use an appropriate torque wrench or torque screwdriver and 2 92 mm driver bit to ensure all 2 92 mm connections are properly torqued 2 92 mm connectors for...

Страница 8: ...evice Front Panel Icon Definitions Refer to the user documentation for required maintenance measures to ensure user safety and or preserve the specified EMC performance The signal pins of this product...

Страница 9: ...written to in order to control the device GREEN The module is ready to be programmed by NI RFSA ACTIVE Indicates the module state OFF The module is in a quiescent state AMBER The module is waiting for...

Страница 10: ...one device a Select the system device with the appropriate downconverter in the configuration tree b In the Associated Devices section use the RF Conditioning drop down listbox to select the NI 5698 c...

Страница 11: ...In the MAX configuration tree expand Devices and Interfaces 2 Expand the Chassis tree to see the list of installed devices and press F5 to refresh the list 3 If the module is still not listed power o...

Страница 12: ...ignal Analyzers Help NI PXIe 5698 Specifications NI RFSA Soft Front Panel NI RFSA Instrument Driver NI RF Vector Signal Analyzers Help NI RFSA Examples Located using the NI Example Finder Located at n...

Страница 13: ...the DoC for your product by visiting ni com certification If your product supports calibration you can obtain the calibration certificate for your product at ni com calibration NI corporate headquart...

Страница 14: ...party legal notices in the readme file for your NI product Refer to the Export Compliance Information at ni com legal export compliance for the NI global trade compliance policy and how to obtain rel...

Отзывы: