Commissioning
5.3 Procedure for commissioning via STARTER
Drive converter cabinet units
Operating Instructions, 07/07, A5E00288214A
141
Calculating the motor/controller data
Figure 5-22 Calculating the motor/controller data
28. In Calculation of the motor/controller data, choose the appropriate default settings for
your device configuration.
Note
If the equivalent circuit diagram data was entered manually (see "Entering the equivalent
circuit diagram data"), the motor/controller data should be calculated without calculating the
equivalent circuit diagram data.
29. Click Continue >.