Operation
6.8 PROFINET IO
Drive converter cabinet units
248
Operating Instructions, 07/07, A5E00288214A
PROFIdrive telegram for cyclic data transmission and non-cyclic services
Telegrams to send and receive process data are available for each drive object of a drive
unit with cyclic process data exchange. In addition to cyclic data transfer, acyclic services
can also be used for parameterizing and configuring the drive. These acyclic services can be
used by the supervisor or the controller.
The total length of the Ethernet frame increases with the number of drive objects in a drive
unit.
Sequence of drive objects in the data transfer
The sequence of drive objects is displayed via a list in p0978[0...15] where it can also be
changed.
Note
The sequence of drive objects in HW Config must be the same as that in the drive (p0978).
NOTICE
A ring-type topology is not permissible.
6.8.3
Hardware setup
6.8.3.1
Configuring SINAMICS drives with PROFINET
Communication Board Ethernet CBE20
The CBE20 option board is inserted in the option slot of the CU320. The CBE20 is equipped
with four ports that can be used to connect the PROFINET sub-network.
Step 7 routing with CBE20
The CBE20 does not support STEP 7 routing between PROFIBUS and PROFINET IO.
Connecting the supervisor
You can go online with the STARTER in a number of ways, which are illustrated below: