Functions, monitoring, and protective functions
9.3 Drive functions
Drive converter cabinet units
326
Operating Instructions, 07/07, A5E00288214A
9.3.6.4
Parameters
•
r0051
Drive data set DDS effective
•
p0130
Motor data sets (MDS) number
•
p0180
Drive data set (DDS) number
•
p0186
Motor data sets (MDS) number
•
p0819[0...2] Copy drive data set DDS
•
p0820
BI: Drive data set selection, bit 0
•
p0821
BI: Drive data set selection, bit 1
•
p0822
BI: Drive data set selection, bit 2
•
p0823
BI: Drive data set selection, bit 3
•
p0824
BI: Drive data set selection, bit 4
•
p0826
Motor changeover, motor number
•
p0827
Motor changeover status word bit number
•
p0828
Motor changeover, feedback signal
•
p0830
Motor changeover, status
•
p0831
Motor changeover, contactor feedback signal
•
p0833
Data set changeover configuration
9.3.7
Friction characteristic curve
Description
The friction characteristic is used to compensate for the frictional torque of the motor and
driven load. A friction characteristic allows the speed controller to be pre-controlled and
improves the control response..
10 points along the characteristic are used for the friction characteristic. The coordinates of
every point along the characteristic are defined by a speed parameter (p382x) and a torque
parameter (p383x) (point 1 = p3820 and p3830).
Features
●
There are 10 points along the characteristic to represent the friction characteristic.
●
An automatic function supports the friction characteristic plot.
●
A connector output (r3841) can be interconnected as friction torque (p1569).
●
The friction characteristic can be activated and de-activated (p3842).