Functions, monitoring, and protective functions
9.4 Extended functions
Drive converter cabinet units
Operating Instructions, 07/07, A5E00288214A
395
MDI mode with the use of PROFIdrive telegram 110.
If connector input p2654 is preset with a connector input ≠ 0 (e.g. with PROFIdrive telegram
110 with r2059[11]), then it will internally manage the control signals "Positioning type
selection", "Positive direction selection" and "Negative direction selection". The following
characteristics are evaluated from the value of the connector input:
●
xx0x = absolute -> p2648
●
xx1x = relative -> p2648
●
xx2x = ABS_POS -> p2648, p2651
●
xx3x = ABS_NEG -> p2648, p2652
Intermediate stop and canceling traversing block
The intermediate stop is activated by a 0 signal at p2640. After activation, the system brakes
with the parameterized deceleration value (p2620 or p2645).
The current traversing task can be canceled by a 0 signal at p2641. After activation, the
system brakes with the maximum deceleration (p2573).
The "intermediate stop" and "cancel traversing task" functions are only effective in the
modes "traversing blocks" and "direct setpoint input/MDI".
Function diagram
FD 3618
EPOS - direct setpoint specification mode/MDI, dynamic values
FD 3620
EPOS - direct setpoint specification mode/MDI
Parameter
•
p2577
BI: EPOS modulo offset activation
•
p2642
CI: EPOS direct setpoint input/MDI, position setpoint
•
p2643
CI: EPOS direct setpoint input/MDI, velocity setpoint
•
p2644
CI: EPOS direct setpoint input/MDI, acceleration override
•
p2645
CI: EPOS direct setpoint input/MDI, delay override
•
p2648
BI: EPOS direct setpoint input/MDI, positioning type
•
p2649
BI: EPOS direct setpoint input/MDI, acceptance type
•
p2650
BI: EPOS direct setpoint input/MDI, setpoint acceptance edge
•
p2651
BI: EPOS direct setpoint input/MDI, positive direction selection
•
p2652
BI: EPOS direct setpoint input/MDI, negative direction selection
•
p2653
BI: EPOS direct setpoint input/MDI, setup selection
•
p2654
CI: EPOS direct setpoint input/MDI, mode adaptation
•
p2690
CO: EPOS position, fixed setpoint
•
p2691
CO: EPOS velocity, fixed setpoint
•
p2692
CO: EPOS acceleration override, fixed setpoint
•
p2693
CO: EPOS delay override, fixed setpoint