Functions, monitoring, and protective functions
9.4 Extended functions
Drive converter cabinet units
380
Operating Instructions, 07/07, A5E00288214A
Table 9-10 DDS switch without load gearbox position tracking
DDS p186
(MDS)
p187
(encoder_1)
p188
(encoder_2)
p189
(encoder_3)
Encoder
for
position
control
p2502
Mechan.
relationships
p2504/
p2505/
p2506 or
p2503
Load
gearbox
position
tracking
Changeover response
0
0
EDS0
EDS1
EDS2
encoder_1 xxx
disabled ---
1
0
EDS0
EDS1
EDS2
encoder_1 xxx
disabled Switching during pulse
inhibition or operation has
no effect
2
0
EDS0
EDS1
EDS2
encoder_1 yyy
disabled Pulse disabling: Position
actual value
preprocessing is newly
initiated
1)
and reference
bit
2)
is reset.
Operation:
Error message is
generated. Position actual
value preprocessing is
newly initiated
1)
and
reference bit
2)
is reset.
3
0
EDS0
EDS1
EDS2
encoder_2 xxx
disabled
4
0
EDS0
EDS3
EDS2
encoder_2 xxx
disabled
5
1
EDS4
EDS1
EDS2
encoder_1 xxx
disabled
6
2
EDS5
EDS6
EDS7
encoder_1 zzz
disabled
Pulse disabling: Position
actual value
preprocessing is newly
initiated
1)
and reference
bit
3)
is reset.
Operation:
Error message is
generated. Actual position
value conditioning newly
set
1)
and reference bit
3)
is reset.
7
3
EDS0
EDS1
EDS2
encoder_1 xxx
disabled MDS switching alone
during pulse disable or
operation has no effect
1)
Is newly initiated means: For absolute encoders, the absolute value is newly read out, and for incremental encoders, a
restart will take place as after POWER ON.
2)
For incremental encoders, r2684.11 (Reference point set) is reset, and for absolute encoders, the status of
the adjustment (p2507) is reset as well.
3)
For incremental encoders, r2684.11 (reference point set) is reset, and for absolute encoders, the adjustment
status (p2507) is not reset because the EDS differs from the original one.