Setpoint channel and closed-loop control
7.3 V/f control
Drive converter cabinet units
Operating Instructions, 07/07, A5E00288214A
271
Voltage boost during acceleration (p1311)
Voltage boost is only active during acceleration or braking. Voltage boost is only active if the
"Ramp-up active" signal (r1199.0 = 1) is pending.
$FFHO
9IQRUPDO
2XWSXWYROWDJH
S5DWHGPRWRUFXUUHQW[
U&XUUHQWVWDWRUUHVLVWDQFH[
Sb9ROWDJHERRVWRQDFFHOHUDWLRQ
$FFHOHUDWLRQ
9IOLQHDU
S[
3ROHSDLUQR
9PD[
PD[
VHWS
9Q
S
IQ
I
S
I
I
9
9
9
U
Figure 7-7
Voltage boost during acceleration (example: p1300 = 0, p1310 = 0, p1311 > 0)
Function diagram
FP 6300
V/f characteristic and voltage boost
Parameters
•
p0304
Rated motor voltage
•
p0305
Rated motor current
•
r0395
Stator resistance, actual
•
p1310
Permanent voltage boost
•
p1311
Voltage boost during acceleration
•
r1315
Voltage boost total