Functions, monitoring, and protective functions
9.4 Extended functions
Drive converter cabinet units
Operating Instructions, 07/07, A5E00288214A
381
Function diagram
FD 3612
Referencing
FD 3614
Flying referencing
Parameters
•
p2596
BI: EPOS set reference point
•
p2597
BI: EPOS homing type selection
•
p2598
CI: EPOS reference point coordinates signal source
•
p2599
CO: EPOS reference point coordinates value
•
p2600
EPOS search for reference, reference point offset
9.4.6.4
Basic positioner with position tracking
Description
Due to the adjustment of the encoder (p2507, absolute value encoder), the actual position
value in the reference point/adjustment point is set to the position value stored in parameter
p2599. The position zero point is calculated from this axis position. Each half of the encoder
range is placed to the left and right of this position zero point; this is the range in which the
position will be restored after switch-off/switch-on.
Reason: The permissible range of position tracking was displayed based on the range of the
basic positioner.
Note
If position tracking is activated after the adjustment (p2720[0] = 1, activate position gearbox,
position tracking), the adjustment is reset.