Functions, monitoring, and protective functions
9.4 Extended functions
Drive converter cabinet units
394
Operating Instructions, 07/07, A5E00288214A
It is possible to make a flying changeover between the two modes.
If continuous acceptance (p2649 = 1) is activated, changes to the MDI parameters are
accepted immediately. Otherwise the values are only accepted when there is a positive edge
at binector input p2650 (setpoint acceptance edge).
Note
Continuous acceptance p2649 = 1 can only be set with free telegram configuration
p0922 = 999. No relative positioning is allowed with continuous acceptance.
The direction of positioning can be specified using p2651 (positive direction specification)
and p2652 (negative direction specification). If both inputs have the same status, the
shortest distance is traveled during absolute positioning (p2648 = "1") of modulo axes
(p2577 = "1").
To use the positioning function, the drive must be in operating mode (r0002 = 0). The
following options are available for starting positioning:
●
p2649 is "1" and positive edge on p2647
●
p2649 is "0" and p2647 is "1"
–
positive edge on p2650 or
–
positive edge on p2649
RESET
SET
x
y
1
0
1
POWER ON
1
p 2690
p 2691
p 2692
p 2693
&
1
)L[HGSRVLWLRQVHWSRLQW
6HWVHWSRLQWWUDQVIHU
)L[HGYHORFLW\VHWSRLQW
)L[HGYHORFLW\RYHUULGHVHWSRLQW
)L[HGGHOD\RYHUULGHVHWSRLQW
S3RVLWLRQLQJW\SH
S'LUHFWLRQVHOHFWLRQSRVLWLYH
S'LUHFWLRQVHOHFWLRQQHJDWLYH
S6HWSRLQWWUDQVIHUHGJH
S7UDQVIHUW\SH
&RQVWDQWWUDQVIHU12UHODWLYHSRV
S0',VHOHFWLRQ
S'RQRWUHMHFWWUDYHUVLQJWDVN
6HWWLQJYDOXHVSUHVHQW
9DOLGVHWWLQJYDOXHV
S0',VBVHWS
S0',YBVHWS
S0',DBVHWS
S0',DBVHWS
Figure 9-27 Setpoint transfer