![Ronde & Schwarz 1304.0004K03 User Manual Download Page 914](http://html1.mh-extra.com/html/ronde-and-schwarz/1304-0004k03/1304-0004k03_user-manual_1484987914.webp)
Remote Commands
R&S
®
FPL1000
914
User Manual 1178.3370.02 ─ 11
Parameters:
<FileName>
String containing the path and file name of the source file.
<FileName>
String containing the path and name of the target file.
The path may be relative or absolute.
MMEMory:DATA
<FileName>[, <Data>]
MMEMory:DATA?
<FileName>
This command writes block data into a file. The delimiter must be set to EOI to obtain
error-free data transfer.
When you query the contents of a file, you can save them in a file on the remote con-
trol computer.
The command is useful for reading stored settings files or trace data from the instru-
ment or for transferring them to the instrument
Parameters:
<Data>
<block_data>
Data block with the following structure.
#
Hash sign.
<number>
Length of the length information.
<number>
Length information of the binary data (number of bytes).
<data>
Binary data with the indicated <number> of bytes.
Parameters for setting and query:
<FileName>
Example:
MMEM:NAME '\Public\User\Testfile.txt'
Creates a new file called 'testfile.txt'.
MMEM:DATA 'Testfile.txt',#220Contents of the
file
The parameter means:
#2: hash sign and length of the length information (20 bytes = 2
digits)
20: indicates the number of subsequent binary data bytes.
Contents of the file: store 20 binary bytes (characters) to the file.
MMEM:DATA? 'Testfile.txt'
Returns the contents of the file.
MMEMory:DELete:IMMediate
<FileName>
This command deletes a file.
Parameters:
<FileName>
String containing the path and file name of the file to delete.
The path may be relative or absolute.
Managing Settings and Results