![Ronde & Schwarz 1304.0004K03 User Manual Download Page 868](http://html1.mh-extra.com/html/ronde-and-schwarz/1304-0004k03/1304-0004k03_user-manual_1484987868.webp)
Remote Commands
R&S
®
FPL1000
868
User Manual 1178.3370.02 ─ 11
Remote commands exclusive to phase noise markers
CALCulate<n>:DELTamarker<m>:FUNCtion:PNOise:AUTO
............................................... 868
CALCulate<n>:DELTamarker<m>:FUNCtion:PNOise:RESult?
............................................ 868
CALCulate<n>:DELTamarker<m>:FUNCtion:PNOise[:STATe]
............................................. 869
CALCulate<n>:MARKer<m>:FUNCtion:PNOise:AOFF
.......................................................869
CALCulate<n>:MARKer<m>:FUNCtion:PNOise:RESult?
................................................... 869
CALCulate<n>:MARKer<m>:FUNCtion:PNOise[:STATe]
.................................................... 870
CALCulate<n>:DELTamarker<m>:FUNCtion:PNOise:AUTO
<State>
This command turns an automatic peak search for the fixed reference marker at the
end of a sweep on and off.
Suffix:
<n>
.
<m>
Parameters:
<State>
ON | OFF | 0 | 1
OFF | 0
Switches the function off
ON | 1
Switches the function on
Example:
CALC:DELT:FUNC:PNO:AUTO ON
Activates an automatic peak search for the reference marker in
a phase-noise measurement.
Manual operation:
See
CALCulate<n>:DELTamarker<m>:FUNCtion:PNOise:RESult?
This command queries the result of a phase noise measurement.
If necessary, the command activates the measurement first.
This command is only available in the Spectrum application.
Suffix:
<n>
.
<m>
Return values:
<PhaseNoise>
numeric value
The difference in level between the reference point and the
noise power density at the position of the specified delta marker.
Example:
CALC:DELT2:FUNC:PNO:RES?
Outputs the result of phase-noise measurement of the delta-
marker 2.
Usage:
Query only
Setting Basic Spectrum RF Measurement Parameters