Status Areas
Section 5-1
5-1
Status Areas
A Digital I/O Slave Unit has two internal status areas: the Warning Status
Area and the Alarm Status Area. The status flags in these areas are turned
ON and OFF based on the threshold values set by the user for each function
in that Unit.
When any of the bits in the status area of the slaves connected to the Master
Unit turns ON, the corresponding bit (bit 12 is for warning status area notices
and bit 13 is for alarm area notices) of the status flag in the Master Unit turns
ON.
The Digital I/O Slave Unit's status area information can be read by using the
CX-Integrator or explicit messages.
Warning Status Area
The Digital I/O Slave Unit's Warning Status Area contains the following
16 bits. These bits indicate minor errors in the Unit.
Digital I/O Slave Unit
Master Unit
Transmitted
to Master Unit
The Digital I/O Slave Unit has two status areas:
the Warning Status Area and the Alarm Status Area.
The status bit detection allocated to the master is OR of all
slaves
Bit
Content
Description
0
Reserved
---
1
Reserved
---
2
Network Power Voltage Drop Flag
OFF: Normal
ON: Error (Voltage dropped below
threshold.)
Monitors the voltage set as the
threshold for the network power volt-
age monitor function.
3
Unit Maintenance Flag
OFF: Normal
ON: Error (Threshold exceeded.)
Monitors the power ON time warning
value set as the threshold for the Unit
Conduction Time Monitor function.
4
Reserved
---
5
Reserved
---
6
Reserved
---
7
Reserved
---
8
Operation Time Monitor Flag
OFF: Normal
ON: Error (Threshold exceeded.)
Turns ON when the threshold set for
the operation time monitor function is
exceeded.
9
Connected Device Maintenance Flag
OFF: Normal
ON: Error (Threshold exceeded.)
Turns ON when the threshold set for
the contact operation monitor func-
tion or the total ON time monitor func-
tion is exceeded.
10
Reserved
---
11
Reserved
---
12
Reserved
---
13
Reserved
---
Summary of Contents for CRT1 - 10-2009
Page 1: ...Cat No W457 E1 07 CompoNet Slave Units and Repeater Unit CRT1 Series OPERATION MANUAL...
Page 2: ......
Page 3: ...CRT1 Series CompoNet Slave Units and Repeater Unit Operation Manual Revised October 2009...
Page 4: ...iv...
Page 6: ...vi...
Page 10: ...x...
Page 16: ...xvi...
Page 24: ...xxiv Conformance to EC Directives 6...
Page 386: ...362 Units with Connectors Section 6 7...
Page 414: ...390 Temperature Input Units Section 7 5...
Page 430: ...406 Expansion Unit Specifications Section 8 2...
Page 494: ...470 Bit Slave Units with Compact Connectors Section 9 5...
Page 501: ...477 Repeater Unit Section 10 2 Dimensions 42 3 50 3 1 27 5 95 mm...
Page 502: ...478 Repeater Unit Section 10 2...
Page 508: ...484 CX Integrator Section 11 1...
Page 509: ...485 CX Integrator Section 11 1...
Page 602: ...578 Temperature Input Unit Functions Section 11 6...
Page 614: ...590 Device Maintenance Section 12 3...
Page 664: ...640 I O Power Supply Current Appendix E...
Page 672: ...648 Index...
Page 674: ...650 Revision History...