CompoNet Explicit Messages
Appendix A
Reading Operation Time Monitor and Total ON Time/Contact Operation
Counter for All Slave Units at Once
Note
(1) The Attribute (7E hex) is bit 6 of the Generic Status and so the size is fixed at 4 bytes and has the
following format.
•Depending on the Unit size, not all bits are used.
• A value of 14FF is returned for all Units except Mixed I/O Units.
(2) The Attribute (7F hex) is bit 7 of the Generic Status and so the size is fixed at 6 bytes and has the
following format.
•Depending on the Unit size, not all bits are used.
Explicit
message
Read
/write
Function Command
Response
Service
code
Class ID Instance
ID
Command data
Service data
Attribute
ID
Data
Monitor
Status for
Operation
Time Moni-
tor for All
Slave Units
Read at
Once
Read Reads the monitor sta-
tus for total operation
time monitor for all
Slave Units.
0E hex
95 hex
01 hex
7E hex
---
+00: Response size
+01: 02 hex (fixed)
+02: Response area 1
+03: Response area 2
(See note 1.)
Monitor
Status for
Total ON
Time or
Contact
Operation
Counter for
All Slave
Units Read
at Once
Read Reads the monitor sta-
tus for total ON time or
contact operation
counter for all Slave
Units.
0E hex
95 hex
01 hex
7F hex
---
+00: Response size
+01: 08 hex (fixed)
+02: Response area 1
+03: Response area 2
+04: Response area 3
+05: Response area 4
+06: Response area 5
+07: Response area 6
+08: Response area 7
+09: Response area 8
(See note 2.)
+00
Size, 0002
Fixed
+01
+02
IN+OUT combined, terminals 0 to 7
The bit turns ON when the set value is exceeded.
+03
Not used.
Offset (byte)
Up to 32 inputs
Up to 16 inputs
Up to 32 inputs
Inputs and outputs
+00
4
No. of data items (UNIT)
+01
+02
IN Area, terminals 0
to 7
Not used.
OUT Area, terminals
0 to 7
IN Area, terminals 0
to 7
+03
IN Area, terminals 8
to 15
OUT Area, terminals
8 to 15
IN Area, terminals 8
to 15
+04
IN Area, terminals 16
to 23
OUT Area, terminals
0 to 7
OUT Area, terminals
16 to 23
OUT Area, terminals
0 to 7
+05
IN Area, terminals 24
to 31
OUT Area, terminals
8 to 15
OUT Area, terminals
24 to 31
OUT Area, terminals
8 to 15
Summary of Contents for CRT1 - 10-2009
Page 1: ...Cat No W457 E1 07 CompoNet Slave Units and Repeater Unit CRT1 Series OPERATION MANUAL...
Page 2: ......
Page 3: ...CRT1 Series CompoNet Slave Units and Repeater Unit Operation Manual Revised October 2009...
Page 4: ...iv...
Page 6: ...vi...
Page 10: ...x...
Page 16: ...xvi...
Page 24: ...xxiv Conformance to EC Directives 6...
Page 386: ...362 Units with Connectors Section 6 7...
Page 414: ...390 Temperature Input Units Section 7 5...
Page 430: ...406 Expansion Unit Specifications Section 8 2...
Page 494: ...470 Bit Slave Units with Compact Connectors Section 9 5...
Page 501: ...477 Repeater Unit Section 10 2 Dimensions 42 3 50 3 1 27 5 95 mm...
Page 502: ...478 Repeater Unit Section 10 2...
Page 508: ...484 CX Integrator Section 11 1...
Page 509: ...485 CX Integrator Section 11 1...
Page 602: ...578 Temperature Input Unit Functions Section 11 6...
Page 614: ...590 Device Maintenance Section 12 3...
Page 664: ...640 I O Power Supply Current Appendix E...
Page 672: ...648 Index...
Page 674: ...650 Revision History...