38
Communications Cable
Section 2-3
Flat Cable II (DCA5-4F10 Sheathed Flat Cable)
CompoNet-compatible products other than DCA5-4F10 can be used. Confirm
applicability with the manufacturer.
Note
(3) The characteristics of each conductor in Flat Cable I and Flat Cable II
have been adjusted to the application. Check the line insulator colors and
use each line only for the application given in the above table.
(4) For information on applicable CompoNet products and manufacturers, re-
fer to the ODVA home page.
http://www.odva.org/
2-3-2
Criteria for Selecting Cables
Selecting Cable Types
Select the cable type using the following items as conditions.
Conduc-
tor No.
Insulation
color
Application
Nominal
cross-sec-
tion
Allowable
current (A)
1
Red
BS+ (communications power
supply positive side)
0.75 mm
2
5 max.
2
White
BDH (signal high)
0.5 mm
2
---
3
Blue
BDL (signal low)
0.5 mm
2
---
4
Black
BS
−
(communications power
supply negative side)
0.75 mm
2
5 max.
Black: BS
−
Red: BS+
White: BDH
Blue: BDL
Item
Cable type
Round cable I
Round cable II
Flat Cable I
Flat Cable II
Application
• When using com-
mercially available
cable is desirable.
• To provide commu-
nications power
separately.
• When using com-
mercially available
cable is desirable.
• To supply commu-
nications power to
all Slave Units with
the communica-
tions cable.
• To supply commu-
nications power to
all Slave Units with
the communica-
tions cable.
• To supply commu-
nications power to
all Slave Units with
the communica-
tions cable.
• Applications in
environments that
required IP54 com-
pliance (drip-proof,
splash-proof).
Slave
Unit
con-
nec-
tions
Word Slave Units
Supported.
Supported. (See
note 2.)
Bit Slave
Units (com-
munications
section Flat
Cable stan-
dard connec-
tion)
Not supported. (See
note 1.)
Not supported. (See
note 1.)
Supported.
Not supported.
IP54 Bit
Slave
Units
Not supported.
Supported.
Bit Slave Unit (commu-
nications section con-
nector)
Supported.
Supported. (See
note 2.)
Summary of Contents for CRT1 - 10-2009
Page 1: ...Cat No W457 E1 07 CompoNet Slave Units and Repeater Unit CRT1 Series OPERATION MANUAL...
Page 2: ......
Page 3: ...CRT1 Series CompoNet Slave Units and Repeater Unit Operation Manual Revised October 2009...
Page 4: ...iv...
Page 6: ...vi...
Page 10: ...x...
Page 16: ...xvi...
Page 24: ...xxiv Conformance to EC Directives 6...
Page 386: ...362 Units with Connectors Section 6 7...
Page 414: ...390 Temperature Input Units Section 7 5...
Page 430: ...406 Expansion Unit Specifications Section 8 2...
Page 494: ...470 Bit Slave Units with Compact Connectors Section 9 5...
Page 501: ...477 Repeater Unit Section 10 2 Dimensions 42 3 50 3 1 27 5 95 mm...
Page 502: ...478 Repeater Unit Section 10 2...
Page 508: ...484 CX Integrator Section 11 1...
Page 509: ...485 CX Integrator Section 11 1...
Page 602: ...578 Temperature Input Unit Functions Section 11 6...
Page 614: ...590 Device Maintenance Section 12 3...
Page 664: ...640 I O Power Supply Current Appendix E...
Page 672: ...648 Index...
Page 674: ...650 Revision History...