29
Slave Unit Models
Section 1-2
Note
For Bit Slave Units, the external I/O (sensor and actuator) power is also pro-
vided through the Flat Cable from the communications power supply con-
nected to the Master Unit or the Repeater Unit. When calculating the output
current of the communications power supply, always include the external I/O
current consumption for Bit Slave Units.
Digital
I/O
Slave
Units
With MIL Con-
nectors
CRT1-VID16ML(-1)
DIN Track
or Mount-
ing Bracket
MIL connectors
Supplied along
with communica-
tions power
I/O power must be
supplied externally
for connected
devices.
CRT1-VOD16ML(-1)
CRT1-VID32ML(-1)
CRT1-VOD32ML(-1)
CRT1-VMD32ML(-1)
With Screw-less
Clamp Terminal
Blocks
CRT1-ID08SL(-1)
DIN Track
Screw-less
clamp terminal
block
CRT1-OD08SL(-1)
CRT1-ID16SL(-1)
CRT1-OD16SL(-1)
CRT1-MD16SL(-1)
Ana-
log I/O
Slave
Units
With 2-tier
Terminal Block
CRT1-AD04
Terminal block
with M3 screws
---
CRT1-DA02
With e-CON
Connectors
CRT1-VAD04S
DIN Track
or Mounting
Bracket
e-CON
connectors
CRT1-VDA02S
With MIL
Connectors
CRT1-VAD04ML
MIL connectors
CRT1-VDA02ML
Temperature Input Units
CRT1-TS04T
DIN Track
Terminal block
with M3 screws
CRT1-TS04P
Digital I/O Slave Units
Expansion Units
XWT-ID08(-1)
Refer to the follow-
ing section.
XWT-OD08(-1)
XWT-ID16(-1)
XWT-OD16(-1)
Bit
Slave
Units
With
e-CON
Connec-
tors
CRT1B-ID02S(-1)
M4 screw
installation
e-CON connec-
tors
Supplied along with
communications
power (See note.)
CRT1B-OD02S(-1)
IP54 CRT1B-ID02SP(-1)
CRT1B-OD02SP(-1)
CRT1B-ID04SP(-1)
With
Screw-
less
Clamp
Terminal
Blocks
IP54 CRT1B-MD04SLP(-1)
Screw-less
clamp terminal
block
With Compact
Connectors
CRT1B-ID02JS(-1)
M4 screen
mounting
using
CRT1B-
ATT03
Mounting
Bracket
Compact con-
nectors
CRT1B-OD02JS(-1)
CRT1B-ID04JS(-1)
CRT1B-OD04JS(-1)
CRT1B-MD02JS(-1)
CRT1B-MD04JS(-1)
Repeater Units
CRS1-RPT01
DIN Track
or M4
screw
installation
---
Communications
power for the down-
stream line must be
supplied from the
communications
power supply con-
nector.
Name
Model
Slave Unit
installation
I/O connection
method
Internal power
External power
Summary of Contents for CRT1 - 10-2009
Page 1: ...Cat No W457 E1 07 CompoNet Slave Units and Repeater Unit CRT1 Series OPERATION MANUAL...
Page 2: ......
Page 3: ...CRT1 Series CompoNet Slave Units and Repeater Unit Operation Manual Revised October 2009...
Page 4: ...iv...
Page 6: ...vi...
Page 10: ...x...
Page 16: ...xvi...
Page 24: ...xxiv Conformance to EC Directives 6...
Page 386: ...362 Units with Connectors Section 6 7...
Page 414: ...390 Temperature Input Units Section 7 5...
Page 430: ...406 Expansion Unit Specifications Section 8 2...
Page 494: ...470 Bit Slave Units with Compact Connectors Section 9 5...
Page 501: ...477 Repeater Unit Section 10 2 Dimensions 42 3 50 3 1 27 5 95 mm...
Page 502: ...478 Repeater Unit Section 10 2...
Page 508: ...484 CX Integrator Section 11 1...
Page 509: ...485 CX Integrator Section 11 1...
Page 602: ...578 Temperature Input Unit Functions Section 11 6...
Page 614: ...590 Device Maintenance Section 12 3...
Page 664: ...640 I O Power Supply Current Appendix E...
Page 672: ...648 Index...
Page 674: ...650 Revision History...