437
Bit Slave Units with Compact Connectors
Section 9-5
9-5
Bit Slave Units with Compact Connectors
9-5-1
Bit Slaves with Compact Connectors
Connecting to Communications Cables
The following communications connectors can be connected to Bit Slave
Units with Compact Connectors.
Applicable Communications Connectors
The DCN4-TB4 Open Type Connector and DCN4-MD4 Multidrop Connector
cannot be used with Bit Slaves with Compact Connectors. For information on
how to process and attach the communications connectors, refer to
3-3 Pre-
paring Flat Connectors
.
Applicable Functions
Bit Slave Units with Compact Connectors do not include functionality to collect
data to help shorten startup and recovery time for control systems and main-
tenance systems.
For details, refer to
1-1-3 CompoNet Slave Unit Functions
on page 7.
Checking the Communications Power Supply Voltage
Bit Slave Units with Compact Connectors do not support a network power
supply voltage monitor. Use either of the following methods to check the volt-
age if a Flat Cable is connected.
• Connect a Flat Connector Socket connected to a cable to a Flat Connec-
tor Plug or Flat Cable I Multidrop Connector Plug at the location where a
Bit Slave Unit with Compact Connectors is to be connected, secure the
extended cable with the terminal block so as not to cause a short circuit,
and measure the voltage using a voltmeter.
• Use a tester or voltmeter to measure between the V and G terminals of
the I/O connector.
Note
(1) Be careful to not cause a short-circuit when performing the measure-
ment. The system or Unit may be damaged if a short-circuit is created.
(2) Always turn OFF the output from the Output Unit before measuring be-
tween the V and G terminals of the I/O connector. The Unit may be dam-
aged if a short-circuit is made with a signal pin for which the output is ON
when the measurement is performed.
Continuous Short- circuit Protection Circuit
This prevents the network power supply from continuously remaining short-
circuited if a short-circuit occurs in I/O wiring. This protection circuit may
become damaged when a short-circuit occurs, and cause the Unit to not oper-
ate correctly.
Name
Model
Hook
Applicable
communications cable
Open Type Connector (for Unit connection)
HCN-
(Honda Tsushin Kogyo Co.,
Ltd.)
Internal
Round Cable I and
Round Cable II
Flat Connector Plug
DCN4-BR4
Internal
Flat Cable I
DCN5-BR4
Internal
Flat Cable II
Multidrop Connector Plug for Flat Cable I
DCN4-MR4
Internal
Flat Cable I
Summary of Contents for CRT1 - 10-2009
Page 1: ...Cat No W457 E1 07 CompoNet Slave Units and Repeater Unit CRT1 Series OPERATION MANUAL...
Page 2: ......
Page 3: ...CRT1 Series CompoNet Slave Units and Repeater Unit Operation Manual Revised October 2009...
Page 4: ...iv...
Page 6: ...vi...
Page 10: ...x...
Page 16: ...xvi...
Page 24: ...xxiv Conformance to EC Directives 6...
Page 386: ...362 Units with Connectors Section 6 7...
Page 414: ...390 Temperature Input Units Section 7 5...
Page 430: ...406 Expansion Unit Specifications Section 8 2...
Page 494: ...470 Bit Slave Units with Compact Connectors Section 9 5...
Page 501: ...477 Repeater Unit Section 10 2 Dimensions 42 3 50 3 1 27 5 95 mm...
Page 502: ...478 Repeater Unit Section 10 2...
Page 508: ...484 CX Integrator Section 11 1...
Page 509: ...485 CX Integrator Section 11 1...
Page 602: ...578 Temperature Input Unit Functions Section 11 6...
Page 614: ...590 Device Maintenance Section 12 3...
Page 664: ...640 I O Power Supply Current Appendix E...
Page 672: ...648 Index...
Page 674: ...650 Revision History...