326
ZENworks 10 Configuration Management System Administration Reference
n
ov
do
cx (e
n)
16
Ap
ril 20
10
2. Double-click
Administrative Tools
>
Services
.
3. Right-click the
Novell ZENworks Embedded Datastore
service, then click
Stop
,
or select the
Novell ZENworks Embedded Datastore
service, then click on the
toolbar.
On Linux:
At the console prompt, enter
/etc/init.d/./sybase-asa stop
.
1b
Delete the contents of the
database
directory.
The
database
directory is located in
ZENworks_installation_path
on Windows and
in the
/opt/novell/zenworks/
directory on Linux.
2
On the device that has the external Sybase database installed, stop the Novell ZENworks
Embedded Datastore service.
On Windows:
Do the following:
1. From the Windows desktop
Start
menu, click
Settings
>
Control Panel
.
2. Double-click
Administrative Tools
>
Services
.
3. Right-click the
Novell ZENworks Embedded Datastore
service, then click
Stop
, or
select the
Novell ZENworks Embedded Datastore
service, then click on the toolbar.
On Linux:
At the console prompt, enter
/etc/init.d/./sybase-asa stop
.
3
From the device that has the external Sybase database installed, copy all files within the
database
directory to the appropriate directories on the ZENworks Server that has the
embedded Sybase database.
The
database
directory is located in
ZENworks_installation_path
on Windows and in the
/opt/novell/zenworks/
directory on Linux.
4
On the ZENworks Server that has the embedded Sybase database installed, open
zenworks_database.conf
and make sure that it contains the correct path of the database file.
5
On the ZENworks Server that has the embedded Sybase database installed, edit
zdm.xml
(located in
ZENworks_installation_path
\conf\datamodel
on Windows and in
/etc/
opt/novell/zenworks/datamodel
on Linux):
Add the following entry:
<entry key="Embedded">true</entry>
Set the value of the
Server
entry key to 127.0.0.1 (the IP address of the ZENworks Server
that has the embedded Sybase database installed).
Make sure that the value of the
Port
entry key is the port number on which the embedded
Sybase database is running.
Set the value of the
Engine
entry key to the database server name specified during the
installation of the embedded Sybase database.
(Optional) If you’ve specified a unique database name during the installation of the
embedded Sybase database, set the value of the
Database
entry key to the unique
database name.
6
On the ZENworks Server that has the embedded Sybase database installed, restart the
ZENworks services:
On Windows:
Do the following:
1. From the Windows desktop
Start
menu, click
Settings
>
Control Panel
.