MAC215990
184
Revision A
3.
Position the header so that the cutterbar is 254
–
356 mm (10
–
14 in.) off the ground.
Checking sensor upper voltage limit
1031986
A
Figure 3.216: Center-Link
4.
Extend the guard angle until header angle indicator (A)
is at E.
1029102
A
Figure 3.217: Down Stop Washer
5.
Check that the float lock linkage is on the down stops
(washer [A] cannot be moved) at both locations.
NOTE:
If the header is
NOT
on its down stops, the voltage may go
out of range during operation causing a malfunction of the
AHHC system. If the header is not on down stops, refer to
3.11 Leveling Header, page 217