MAC215990
208
Revision A
1016112
Figure 3.266: New Holland Combine Display
5.
When all steps have been completed, the CALIBRATION
COMPLETED message appears on the page.
NOTE:
If the float was set heavier to complete AHHC calibration
procedure, adjust it to the recommended operating float
after the calibration is complete.
Calibrating Reel Height Sensor and Reel Fore-Aft Sensor
–
New Holland CR Series
The reel height sensor and reel fore-aft sensor will need to be calibrated before the auto header height control (AHHC)
system can be used. Calibrating the reel position calibrates the reel height sensor and the reel fore-aft sensor.
DANGER
Ensure that all bystanders have cleared the area.
NOTE:
Changes may have been made to the combine controls or the display since this document was published. Refer to the
combine operator
’
s manual for the most up-to-date information.
NOTE:
This section applies only to 2015 and later CR models (6.80, 6.90, 7.90, 8.90, 9.90, and 10.90).
To calibrate the reel position, follow these steps:
1.
Position the header 254
–
356 mm (10
–
14 in.) off the ground.
IMPORTANT:
Do
NOT
turn off the engine. The combine has to be at full idle for the sensors to calibrate properly.
1016108
A
Figure 3.267: New Holland Combine Display
2.
Select CALIBRATIONS (A) on the main page. The
CALIBRATION page appears.