MAC215990
44
Revision A
1028857
A
B
B
C
C
Figure 3.18: Left Header Endshield
5.
If the clearances at the front of the endshield are
insufficient, adjust the position of hinge arm (A) as follows:
a.
Loosen four nuts (B).
b.
Slide brackets (C) and hinge arm (A) fore or aft as
required to achieve the correct clearance.
c.
Retighten the hardware.
A
D
B
C
A
A
H
E
F
G
ϭϬϰϬϱϲϲ
Figure 3.19: Clearance Specification between Neck Shield and Panel
6.
Measure clearance (A) between neck shield (B) and panel (C). The clearance must be at least 3 mm (0.12 in.). To adjust
the clearance, loosen two nuts (D), move neck panel (B), and tighten nuts (D).
7.
Measure clearance (E) between panel (C) and endshield (F). The clearance must be 1
–
3 mm (0.04
–
0.12 in.). To adjust
the clearance, loosen two nuts (G), slide bracket (H) up or down, and re-tighten the nuts. Make sure the endshield
does
NOT
rest on neck panel (B).