MAC215990
191
Revision A
1003674
A
Figure 3.231: New Holland Combine Display
9.
Select HEADER HEIGHT/TILT (A). The PARAMETER page
appears.
1003675
A
B
Figure 3.232: New Holland Combine Display
10. Select LEFT HEADER HEIGHT SEN (A), and then select
GRAPH button (B). The voltage reading appears at the top
of the page.
11. Raise and lower the header to see the full range of
voltage readings.
12. Compare the voltage readings on the display to voltage
ranges specified in
3.10.2 Recommended Sensor Output
Voltages for Combines, page 183
Header Settings Quick Reference
–
New Holland CR Series
Use the information in the following table to quickly reference the recommended settings for a header paired with a New
Holland CR Series combine.
NOTE:
Changes may have been made to the combine controls or the display since this document was published. Refer to the
combine operator
’
s manual for the most up-to-date information.
Header Settings
–
New Holland CR Series
Setup Parameter
Suggested Setting
Cutting type
Platform
Header sub type
80/90
Autofloat
Installed
Auto header lift
Installed
Manual HHC raise/lower rate
Set for best performance
HHC height sensitivity
Set for best performance