MAC215990
257
Revision A
ϭϬϰϬϳϵϲ
A
Figure 4.16: Reel
A - Reel U-joint (One Place)
74
Every 500 Hours
Maintenance is required to keep your machine operating at peak performance. It also allows you to do a visual inspection
of the machine that may help identify issues early.
Use high temperature extreme pressure (EP2) performance grease with 1% max molybdenum disulphide (NLGI Grade 2)
lithium base unless otherwise specified.
1036850
A
Figure 4.17: Every 500 Hours
A - Wheel Bearings (Four Places)
74. U-joint has an extended lubrication cross and bearing kit. Stop greasing when greasing becomes difficult or if U-joint
stops taking grease. Overgreasing will damage U-joint. Six to eight pumps are sufficient at first grease (factory).
Increase grease interval as U-joint wears and requires more than six pumps.