Waveform Generator
19
Keysight InfiniiVision 3000T X-Series Oscilloscopes User's Guide
315
•
Frequency-Shift Keying Modulation (FSK)
— the output frequency "shifts"
between the original carrier frequency and a "hop frequency" at the
specified FSK rate. The FSK rate specifies a digital square wave
modulating signal. See
“To set up Frequency-Shift Keying Modulation
To set up Amplitude Modulation (AM)
In the Waveform Generator Modulation Menu (under
[Wave Gen] > Settings >
Modulation
):
1
Press the
Type
softkey and turn the Entry knob to select
Amplitude Modulation
(AM)
.
2
Press the
Waveform
softkey and turn the Entry knob to select the shape of the
modulating signal:
•
Sine
•
Square
•
Ramp
When the
Ramp
shape is selected, a
Symmetry
softkey appears so that you can
specify the amount of time per cycle that the ramp waveform is rising.
3
Press the
AM Freq
softkey and turn the Entry knob to specify the frequency of
the modulating signal.
4
Press the
AM Depth
softkey and turn the Entry knob to specify the amount of
amplitude modulation.
AM Depth refers to the portion of the amplitude range that will be used by the
modulation. For example, a depth setting of 80% causes the output amplitude
to vary from 10% to 90% (90% – 10% = 80%) of the original amplitude as the
modulating signal goes from its minimum to maximum amplitude.
The following screen shows an AM modulation of a 100 kHz sine wave carrier
signal.
Summary of Contents for DSOX3012T
Page 78: ...78 Keysight InfiniiVision 3000T X Series Oscilloscopes User s Guide 2 Horizontal Controls...
Page 88: ...88 Keysight InfiniiVision 3000T X Series Oscilloscopes User s Guide 3 Vertical Controls...
Page 98: ...98 Keysight InfiniiVision 3000T X Series Oscilloscopes User s Guide 4 FFT Spectral Analysis...
Page 148: ...148 Keysight InfiniiVision 3000T X Series Oscilloscopes User s Guide 7 Digital Channels...
Page 154: ...154 Keysight InfiniiVision 3000T X Series Oscilloscopes User s Guide 8 Serial Decode...
Page 160: ...160 Keysight InfiniiVision 3000T X Series Oscilloscopes User s Guide 9 Display Settings...
Page 232: ...232 Keysight InfiniiVision 3000T X Series Oscilloscopes User s Guide 13 Acquisition Control...
Page 242: ...242 Keysight InfiniiVision 3000T X Series Oscilloscopes User s Guide 14 Cursors...
Page 288: ...288 Keysight InfiniiVision 3000T X Series Oscilloscopes User s Guide 16 Mask Testing...
Page 320: ...320 Keysight InfiniiVision 3000T X Series Oscilloscopes User s Guide 19 Waveform Generator...
Page 340: ...340 Keysight InfiniiVision 3000T X Series Oscilloscopes User s Guide 21 Print Screens...
Page 374: ...374 Keysight InfiniiVision 3000T X Series Oscilloscopes User s Guide 23 Web Interface...
Page 394: ...394 Keysight InfiniiVision 3000T X Series Oscilloscopes User s Guide 24 Reference...