MIL-STD-1553/ARINC 429 Triggering and Serial Decode
31
Keysight InfiniiVision 3000T X-Series Oscilloscopes User's Guide
487
Searching for MIL-STD-1553 Data in the Lister
The oscilloscope's search capability lets you search for (and mark) certain types of
MIL-STD-1553 data in the Lister. You can use the
[Navigate]
key and controls to
navigate through the marked rows.
1
With MIL-STD-1553 selected as the serial decode mode, press
[Search]
.
2
In the Search Menu, press the
Search
softkey; then, turn the Entry knob to select
the serial slot (Serial 1 or Serial 2) on which the MIL-STD-1553 signal is being
decoded.
3
Press
Search
; then, select from these options:
•
Data Word Start
— finds the start of a Data word (at the end of a valid Data
Sync pulse).
•
Command/Status Word Start
— finds the start of Command/Status word (at the
end of a valid C/S Sync pulse).
•
Remote Terminal Address
— finds the Command/Status word whose RTA
matches the specified value. The value is specified in hex.
When this option is selected, the
RTA
softkey becomes available and lets you
select the hex Remote Terminal Address value to find.
•
Remote Terminal A 11 Bits
— finds the RTA and the remaining 11 bits
that match the specified criteria.
When this option is selected, these softkeys become available:
•
The
RTA
softkey lets you select the hex Remote Terminal Address value.
•
The
Bit Time
softkey lets you select the bit time position.
•
The
0 1 X
softkey lets you set the bit time position value as a 1, 0, or X
(don't care).
•
Parity Error
— finds (odd) parity bits that are incorrect for the data in the word.
•
Sync Error
— finds invalid Sync pulses.
•
Manchester Error
— finds Manchester encoding errors.
For more information on searching data, see
For more information on using the
[Navigate]
key and controls, see
Summary of Contents for DSOX3012T
Page 78: ...78 Keysight InfiniiVision 3000T X Series Oscilloscopes User s Guide 2 Horizontal Controls...
Page 88: ...88 Keysight InfiniiVision 3000T X Series Oscilloscopes User s Guide 3 Vertical Controls...
Page 98: ...98 Keysight InfiniiVision 3000T X Series Oscilloscopes User s Guide 4 FFT Spectral Analysis...
Page 148: ...148 Keysight InfiniiVision 3000T X Series Oscilloscopes User s Guide 7 Digital Channels...
Page 154: ...154 Keysight InfiniiVision 3000T X Series Oscilloscopes User s Guide 8 Serial Decode...
Page 160: ...160 Keysight InfiniiVision 3000T X Series Oscilloscopes User s Guide 9 Display Settings...
Page 232: ...232 Keysight InfiniiVision 3000T X Series Oscilloscopes User s Guide 13 Acquisition Control...
Page 242: ...242 Keysight InfiniiVision 3000T X Series Oscilloscopes User s Guide 14 Cursors...
Page 288: ...288 Keysight InfiniiVision 3000T X Series Oscilloscopes User s Guide 16 Mask Testing...
Page 320: ...320 Keysight InfiniiVision 3000T X Series Oscilloscopes User s Guide 19 Waveform Generator...
Page 340: ...340 Keysight InfiniiVision 3000T X Series Oscilloscopes User s Guide 21 Print Screens...
Page 374: ...374 Keysight InfiniiVision 3000T X Series Oscilloscopes User s Guide 23 Web Interface...
Page 394: ...394 Keysight InfiniiVision 3000T X Series Oscilloscopes User s Guide 24 Reference...