Appendix Communication Protocol GK600 User Manual
- 254 -
Application layer protocol
data unit
Data length (number of
bytes)
Range
Parameter
1
0x03
Number of read bytes
1
2* number of registers
Register content
2* number of registers
Check
LRC or CRC
Parameter 0x06
(
0x41
)
: write register content (0x41 saved at power loss)
Request format is shown in appendix table 8.
Appendix Table 8
Application layer protocol
data unit
Data length (number of
bytes)
Range
Parameter
1
0x06
Register address
2
0x0000~0xFFFF
Register content
2
0x0000~0xFFFF
Check
LRC or CRC
Response format is shown in appendix table 9.
Appendix Table 9
Application layer protocol
data unit
Data length (number of
bytes)
Range
Parameter
1
0x06
Register address
2
0x0000~0xFFFF
Register content
2
0x0000~0xFFFF
Check
LRC or CRC
Some parameters of the drive are reserved and cannot be modified by communication setting.
The list of these parameters is shown in appendix table 10.
Appendix Table 10