Chapter 6 Specification of Parameters
GK600 User Manual
- 218 -
Ones place: frequency setting
0: Multi-step frequency 8 (F1-10)
1~7: same as F2-01
Tens place: run direction (same as F2-01)
Hundreds place: Accel/Decel time option (same as F2-01)
F2-18
Run time of step 8
Range: 0.0~6000.0s(min)
Factory default:
0.0s
Sets the run time of step 8 of simple PLC. The time unit is set by thousands place of F2-00.
F2-19
Setting of step 9
Range: 000~327
Factory default:
000
Ones place: frequency setting
0: Multi-step frequency 9 (F1-11)
1~7: same as F2-01
Tens place: run direction (same as F2-01)
Hundred's place: Accel/Decel time option (same as F2-01)
F2-20
Run time of step 9
Range: 0.0~6000.0s(min)
Factory default:
0.0s
Sets the run time for step 9 of simple PLC. The time unit is set by thousands place of F2-00.
F2-21
Setting of step 10
Range: 000~327
Factory default:
000
Ones place: frequency setting
0: Multi-step frequency 10 (F1-12)
1~7: same as F2-01
Tens place: run direction (same as F2-01)
Hundreds place: Accel/Decel time option (same as F2-01)
F2-22
Run time of step 10
Range: 0.0~6000.0s(min)
Factory default:
0.0s
Sets the run time of step 10 of simple PLC. The time unit is set by thousands place of F2-00.
F2-23
Setting of step 11
Range: 000~327
Factory default:
000
Ones place: frequency setting
0: Multi-step frequency 11 (F1-13)
1~7: same as F2-01