GK600 User Manual Chapter 6 Specification of Parameters
-
223 -
F3-06
Cycle of wobble frequency
Range: 0.1s~999.9s
Factory default:
0.0s
The time of the completion of a complete process of wobble frequency
F3-07
Triangular wave ramp-up time
Range: 0.0%~100.0%
Factory default:
0.0%
Sets the wobble frequency run time of ramp-up step.
Triangular wave ramp up time = F3-07 × F3-06
Wobble frequency ramp-down time = F3-06 - triangular wave ramp-up time
ATTENTION:
The current wobble frequency status can be cleared by digital input terminal "clear wobble
frequency status " in stop status.If the output frequency exceeds upper limit frequency or
lower limit frequency during the running at wobble frequency, digital output terminal " wobble
frequency attains to upper or lower limit frequency " outputs ON signal
Parameters F3-08~F3-11 are for fixed-length stop.
F3-08
Length unit
Range: 0~1
Factory default: 0
0: m
1: 10m
F3-09
Length setting
Range: 0~65535
Factory default:
1000
Sets the length value of fixed-length stop. When set to 0, fixed-length stop function is enabled,
but the actual length is still calculated. When it is detected the actual length attains this set
value, digital output terminal "length attained" will output ON signal and perform the command
set by F3-11.
F3-10
Pulse number per meter
Range: 0.1~6553.5
Factory default:
100.0
Input pulse is received via digital input terminal "length count"; the pulse number per meter is
set here.
F3-11
Action when the length
attained
Range: 0~1
Factory default: 0
0: Not stop 1: Stop
This parameter sets the action of the drive when actual length attains the length set by F3-09.
Actual length can be cleared through digital input terminal "length clear".