GK600 User Manual Chapter 6 Specification of Parameters
-
219 -
Tens place: run direction (same as F2-01)
Hundreds place: Accel/Decel time option (same as F2-01)
F2-24
Run time of step 11
Range: 0.0~6000.0s(min)
Factory default:
0.0s
Sets the run time of step 11 of simple PLC. The time unit is set by thousands place of F2-00.
F2-25
Setting of step 12
Range: 000~327
Factory default:
000
Ones place: frequency setting
0: Multi-step frequency 12 (F1-14)
1~7: same as F2-01
Tens place: run direction (same as F2-01)
Hundreds place: Accel/Decel time option (same as F2-01)
F2-26
Running time of step 12
Range: 0.0~6000.0s(min)
Factory default:
0.0s
Sets the run time of step 12 of simple PLC. The time unit is set by thousands place of F2-00.
F2-27
Setting of step 13
Range: 000~327
Factory default:
000
Ones place: frequency setting
0: The time unit is set by thousands place of F2-00.
1~7: same as F2-01
Tens place: run direction (same as F2-01)
Hundreds place: Accel/Decel time option (same as F2-01)
F2-28
Run time of step 13
Range: 0.0~6000.0s(min)
Factory default:
0.0s
Sets the run time of step 13 of simple PLC. The time unit is set by thousands place of F2-00.
F2-29
Setting of step 14
Range: 000~327
Factory default:
000
Ones place: frequency setting
0: Multi-step frequency 14 (F1-16)
1~7: same as F2-01
Tens place: run direction (same as F2-01)
Hundreds place: Accel/Decel time option (same as F2-01)