Chapter 6 Specification of Parameters GK600 User Manual
- 162 -
frequency is attained, this terminal output ON.
35~99: Reserved
C1-04
Y1 output time delay
Range: 0.0s~3600.0s
Factory default: 0.0s
C1-05
Y2 output time delay
Range: 0.0s~3600.0s
Factory default: 0.0s
C1-06
Control board relay
output time delay
Range: 0.0s~3600.0s
Factory default: 0.0s
C1-07
Option board relay
output time delay
Range: 0.0s~3600.0s
Factory default: 0.0s
These four parameters define the delay response time of digital output terminals Y1 & Y2,
control board relay and option board relay.
ATTENTION:
When Y2/DO terminal is used as high-speed pulse output (set by C3-02), delay time set by
C1-05 is disabled.
C1-08
Enabled state of digital
output
Range: 0000~1111
Factory default:
0000
Ones place: Y1
0: Positive logic; ON when current flows through
1: Negative logic; ON when no current flows through
Tens place: Y2 (same as Y1)
Hundreds place: control board relay output
0: Positive logic; ON when there is coil excitation
1: Negative logic; ON when there is no coil excitation
Thousands place: option board relay output (same as control board relay)
Wiring diagram of digital output terminal is shown as Fig. 6-21:
Fig. 6-21
C1-09
Detected object of FREQ
detection (FDT)
Range: 00~11
Factory default:
00
Ones place: FDT1 detected object
0: Set value of speed (frequency after Accel/Decel)
+24V
变
频
器
COM
(
i=1,2
)
Y(i)
继电器
Drive