GK600 User Manual
Chapter 6 Specification of Parameters
-
149 -
16: Multi-step frequency terminal 2
17: Multi-step frequency terminal 3
18: Multi-step frequency terminal 4
16-step frequency can be attained via combination of multi-step frequency terminals 1~4, as
shown in Table 6-7:
Table 6-7
Multi-step
frequency
terminal 4
Multi-step
frequency
terminal 3
Multi-step
frequency
terminal 2
Multi-step
frequency
terminal 1
Frequency setting
OFF
OFF
OFF
OFF
Multi-step frequency 0
(F1-00)
OFF
OFF
OFF
ON
Multi-step frequency 1
(F1-01)
OFF
OFF
ON
OFF
Multi-step frequency 2
(F1-04)
OFF
OFF
ON
ON
Multi-step frequency 3
(F1-05)
OFF
ON
OFF
OFF
Multi-step frequency 4
(F1-06)
OFF
ON
OFF
ON
Multi-step frequency 5
(F1-07)
OFF
ON
ON
OFF
Multi-step frequency 6
(F1-08)
OFF
ON
ON
ON
Multi-step frequency 7
(F1-09)
ON
OFF
OFF
OFF
Multi-step frequency 8
(F1-10)
ON
OFF
OFF
ON
Multi-step frequency 9
(F1-11)
ON
OFF
ON
OFF
Multi-step frequency 10
(F1-12)
ON
OFF
ON
ON
Multi-step frequency 11
(F1-13)
ON
ON
OFF
OFF
Multi-step frequency 12
(F1-14)
ON
ON
OFF
ON
Multi-step frequency 13
(F1-15)
ON
ON
ON
OFF
Multi-step frequency 14
(F1-16)
ON
ON
ON
ON
Multi-step frequency 15
(F1-17)
19: Accel/Decel time determinant 1