Chapter 5 List of Parameters GK600 User Manual
- 82 -
Parameter
Designation
Scope
Factory
default
Attr
14: Fault output
15: Alarm output
16: Drive (motor) overloaded alarm
17: Drive overheat alarm
18: Zero current detection
19: X1
20: X2
21: Motor 1/ 2 indication
22: Set count value attained
23: Designated count value attained
24: Length attained
25: Consecutive run time attained
26: Accumulative run time attained
27: Brake control
28: Reserved
29: Reserved
30: PLC step completed
31: PLC cycle completed
32: Wobble frequency attains to
upper or lower limit frequency
33: Upper/lower limit of set FREQ
attained
34: Target FREQ attained (set by
C2-29)
35~99: Reserved
C1-04 Y1 output time delay
0.0s~3600.0s
0.0s
△
C1-05 Y2 output time delay
0.0s~3600.0s
0.0s
△
C1-06
Control board relay output
time delay
0.0s~3600.0s
0.0s
△
C1-07
Option board relay output
time delay
0.0s~3600.0s
0.0s
△
C1-08
Enabled state of digital
output
Ones place: Y1
0: Positive logic
1: Negative logic
Tens place: Y2 (same as ones place)
Hundreds place: control board relay
output (same as ones place)
Thousands place: option board relay
output (same as ones place)
0000
×
C1-09
Detected object of FREQ
detection (FDT)
Ones place: FDT1 detected object
0: Speed set value (FREQ after
Accel/Decel)
00
△