GK600 User Manual
Chapter 6 Specification of Parameters
-
197 -
place of E0-02. Time unit is set at hundreds place of E0-02. When this parameter value is set to
0, this function is enabled.
E0-05
Mechanical brake control
Range: 0~1
Factory default: 0
0: Disabled
1: Enabled
Process of mechanical brake control is as shown as Fig. 6-47 below:
Fig. 6-47
1)
Upon the receipt of run command, the drive will accelerate to the mechanical brake open
frequency set by E0-06.
2)
When frequency attains the value as set by E0-06, digital output terminal "mechanical
brake control" outputs ON to control the mechanical brake open.
3)
Perform constant-speed running at mechanical brake open frequency. During this period,
the drive keeps the output current no higher than the current as set by E0-07.
4)
When the run time at mechanical brake open frequency attains set value of E0-08, the
drive will accelerate to set frequency.
5)
Upon the receipt of stop command, the drive decelerate to mechanical brake close
frequency set by E0-09 and maintains constant-speed run at this frequency.
6)
When the run frequency attains the set value of E0-09, waiting a period of time set by
E0-10, then digital output terminal "mechanical brake control" will output OFF signal to
control mechanical brake close.
7)
When the time of output OFF signal "mechanical brake control" attains the set value of
E0-11, the drive will block the output and stop.
E0-06
Mechanical brake open
frequency
Range: 0.00Hz~10.00Hz
Factory default:
2.50Hz
运行命令
频率
时间
时间
E0-08
E0-10
OFF
电流
时间
抱闸控制
时间
E0-06
E0-09
E0-07
E0-11
ON
OFF
ON
OFF
Run command
Time
Time
Time
Time
Frequency
Current
Mechanical brake control