3.6.5 Terminal Screw and Wiring Requirement
Table 3-4 Terminal screw and wiring requirement
■GK600-2T
B Single-phase / Three-phase 220V input
Drive model
Power terminal
Ground terminal
Cable
requirement
(mm
2
)
Screw
Torque
(kgf.cm)
Cable
requirement
(mm
2
)
Screw
Torque
(kgf.cm)
GK600-2T0.4B
2.5
M3.5
10±0.5
2.5
M3.5
10±0.5
GK600-2T0.75B
2.5
M3.5
10±0.5
2.5
M3.5
10±0.5
GK600-2T1.5B
2.5
M3.5
10±0.5
2.5
M3.5
10±0.5
GK600-2T2.2B
2.5
M4
14±0.5
2.5
M4
14±0.5
■GK600-2T
Three-phase 220V input
Drive model
Power terminal
Ground terminal
Cable
requirement
(mm
2
)
Screw
Torque
(kgf.cm)
Cable
requirement
(mm
2
)
Screw
Torque
(kgf.cm)
GK600-2T3.7B
4
M4
14±0.55
5
4
M4
14±0.5
GK600-2T5.5B
4
M4
28±0.5
4
M5
28±0.5
GK600-2T7.5B
6
M5
28±0.5
6
M5
28±0.5
GK600-2T11(B)
10
M6
48±0.5
10
M6
48±0.5
GK600-2T15(B)
16
M6
48±0.5
16
M6
48±0.5
GK600-2T18.5(B)
25
M8
120±0.5
5
16
M8
120±0.5
GK600-2T22(B)
25
M8
120±0.5
16
M8
120±0.5
GK600-2T30
50
M10
250±0.5
25
M8
120±0.5
GK600-2T37
70
M10
250±0.5
35
M8
120±0.5
GK600-2T45
95
M12
440±0.5
50
M12
440±0.5
GK600-2T55
120
M12
440±0.5
70
M12
440±0.5
GK600-2T75
150
M12
440±0.5
95
M12
440±0.5
GK600-2T90
185
M12
440±0.5
95
M12
440±0.5
GK600-2T110
240
M16
690±0.5
120
M16
690±0.5