Chapter 5 List of Parameters GK600 User Manual
- 102 -
Parameter
Designation
Scope
Factory
default
Attr
0: Multi-step FREQ 9 (F1-11)
1~7: Same as F2-01
Tens place: run direction (same as
F2-01)
Hundreds place: ACC/DEC time option
(same as F2-01)
F2-20 Run time of step 9
0.0s(min)~6000.0s(min)
0.0s
△
F2-21 Setting of step 10
Ones place: FREQ setting
0: multi-step FREQ 10 (F1-12)
1~7: same as F2-01
Tens place: run direction (same as
F2-01)
Hundreds place: Accel/Decel time
option (same as F2-01)
000
×
F2-22 Run time of step 10
0.0s(min)~6000.0s(min)
0.0s
△
F2-23 Setting of step 11
Ones place: FREQ setting
0: Multi-step FREQ 11 (F1-13)
1~7: Same as F2-01
Tens place: run direction (same as
F2-01)
Hundreds place: Accel/Decel time
option (same as F2-01)
000
×
F2-24 Run time of step 11
0.0s(min)~6000.0s(min)
0.0s
△
F2-25 Setting of step 12
Ones place: FREQ setting
0: Multi-step FREQ 12 (F1-14)
1~7: Same as F2-01
Tens place: run direction (same as
F2-01)
Hundreds place: Accel/Decel time
option (same as F2-01)
000
×
F2-26 Run time of step 12
0.0s(min)~6000.0s(min)
0.0s
△
F2-27 Setting of step 13
Ones place: FREQ setting
0: Multi-step FREQ 13 (F1-15)
1~7: Same as F2-01
Tens place: run direction (same as
F2-01)
Hundreds place: Accel/Decel time
option (same as F2-01)
000
×
F2-28 Run time of step 13
0.0s(min)~6000.0s(min)
0.0s
△
F2-29 Setting of step 14
Ones place: FREQ setting
0: Multi-step FREQ 14 (F1-16)
1~7: Same as F2-01
000
×