GK600 User Manual
Chapter 5 List of Parameters
- 91 -
Parameter
Designation
Scope
Factory
default
Attr
d3-13
Flux weakening coeff 2 of
motor 2
0.0000~1.0000
Model
dependent
×
d3-14
Flux weakening coeff 3 of
motor 2
0.0000~1.0000
Model
dependent
×
d3-15 Reserved
Reserved
Reserved ×
d3-16 Reserved
Reserved
Reserved ×
d3-17 Reserved
Reserved
Reserved ×
d3-18 Reserved
Reserved
Reserved ×
d3-19 Reserved
Reserved
Reserved ×
d3-20 Reserved
Reserved
Reserved ×
d3-21 Reserved
Reserved
Reserved ×
d3-22 Autotuning of motor 2
0: No autotuning
1: Static autotuning
2: Rotary autotuning
0
×
d3-23
Overload protection mode
of motor 2
0: No action
1: Judged by motor current
2: Judged by temperature transducer
1
×
d3-24
Overload protection
detection time of motor 2
0.1min~15.0min
5.0min
×
d3-25
Input channel of motor 2
temperature transducer
signal
0: AI1
1: AI2
2: EAI (on IO option)
0
×
d3-26
Thermal protection
threshold of motor 2
temperature transducer
0.00V~10.00V
10.00V
×
Group d4 V/f Control Parameter of Motor 2
d4-00 V/f curve setting
0: Linear V/f
1: Various segments V/f
(d4-01~d4-08)
2: 1.2nd power
3: 1.4th power
4: 1.6th power
5: 1.8th power
6: 2.0nd power
7: V/f separated mode 1
8: V/f separated mode 2
0
×
d4-01 V/f FREQ value f3
0.00Hz~rated FREQ of motor
50.00Hz ×
d4-02 V/f voltage value V3
0.0%~100.0%
100.0%
×
d4-03 V/f FREQ value f2
d4-05~d4-01
0.00Hz
×
d4-04 V/f voltage value V2
0.0%~100.0%
0.0%
×