Chapter 6 Specification of Parameters
GK600 User Manual
- 234 -
U0-44
Higher-bit numbers of
terminal UP/DOWN stored
value
Range: -1~1
Factory default: 0
U0-45
Lower-bit numbers of
terminal UP/DOWN stored
value
Range: 0.00~655.35 Hz
Factory default:
0.00Hz
U0-52
Center FREQ of wobble
FREQ
Range: 0~600.00 Hz
Factory default:
0.00 Hz
Group U1 History Fault
U1-00 History fault 1 (latest)
Range: 0~46
Factory default: 0
U1-01 Run frequency at fault 1
Range: 0.00Hz~600.00Hz
Factory default:
0.00Hz
U1-02 Output current at fault 1
Range: 0.0A~6553.5A
Factory default: 0.0A
U1-03 Bus voltage at fault 1
Range: 0V~10000V
Factory default: 0V
U1-04
Temperature 1 of heat sink at
fault 1
Range: -40.0
℃
~100.0
℃
Factory default: 0.0
℃
U1-05
Temperature 2 of heat sink at
fault 1
Range: -40.0
℃
~100.0
℃
Factory default: 0.0
℃
U1-06
Input terminal status at fault
1
Range: 0000~FFFF
Factory default: 0000
U1-07
Output terminal status at
fault 1
Range: 0000~FFFF
Factory default: 0000
U1-08 Cumulative run time at fault 1 Range: 0h~65535h
Factory default: 0h
Check the information of the latest fault. See Chapter 7 for details of fault codes.
U1-09 Code of fault 2
Range: 0~45
Factory default: 0
U1-10 Run frequency at fault 2
Range: 0.00Hz~600.00Hz
Factory default:
0.00Hz
U1-11 Output current at fault 2
Range: 0.0A~6553.5A
Factory default: 0.0A
U1-12 Bus voltage at fault 2
Range: 0V~10000V
Factory default: 0V
U1-13
Temperature 1 of heat sink at
fault 2
Range: -40.0
℃
~100.0
℃
Factory default: 0.0
℃
U1-14
Temperature 2 of heat sink at
fault 2
Range: -40.0
℃
~100.0
℃
Factory default: 0.0
℃
U1-15
Input terminal status at fault
2
Range: 0000~FFFF
Factory default: 0000