406
Ion Classic User Manual
There are 10 levels of background priority for submasters. 1 is the lowest and 10 is the
highest.
Up Time
This is the time for the submaster to fade from its home position to its target position (0 to Full
if additive, Full to 0 if inhibitive). The default time is 0.
Dwell Time
This is the time the submaster look will hold before starting the downfade. This can be set to a
specified time, or to “Hold” or “Manual”. “Hold” time maintains the submaster values until
the bump is pressed a second time. “Manual” time applies the submaster values only as long
as the bump is held. The default is “Manual”.
Down Time
This is the time for the submaster to fade from its target position to its home position. The
default time is 0.
Stomp Mode
Stomp happens when all the content owned by a submaster is now being controlled by other
targets. The submaster is being removed from the background , and once that happens, it
would not be eligible to fade back. You can assign behavior that will happen when a
submaster is stomped.
The following are Stomp Mode options:
•
Off When Stomped - puts the content into an off state, the same behavior encountered
when pressing {Off} & [Load].
•
Unload When Stomped - unloads the fader.
•
Nothing When Stomped - no action happens to the submaster.
•
Release When Stomped -This function behaves the same as Off When Stomped.
Unmark at 0%
When this option is on, marked content controlled by the submaster will automatically be
released when the fader reaches 0%. When the bump button is next pressed, the submaster
will fire. If this option is off, you would need to first press the bump button to reset the
submaster before pressing the bump again to fire it.
Note:
This option is for submasters that are set to Intensity Master.
Exclude
Those exclusions include:
•
Exclude From Record - output is not recorded into any other record target.
•
Exclude From Grandmaster - content cannot be mastered by a grandmaster.
•
Exclude From Inhibitive Sub - content cannot be mastered by an inhibitive submaster
•
Exclude From Solo - content will ignore solo. See
Configuration (on the facing page)
for more information on solo.
Summary of Contents for Element Classic
Page 1: ...Ion Classic User Manual Version 3 1 1 4310M1210 3 1 1 RevA 2022 03...
Page 92: ...78 Ion Classic User Manual...
Page 212: ...198 Ion Classic User Manual...
Page 274: ...260 Ion Classic User Manual...
Page 275: ...Mark 261 Chapter 9 Mark About Mark 262 AutoMark 262 Referenced Marks 263...
Page 308: ...294 Ion Classic User Manual...
Page 346: ...332 Ion Classic User Manual...
Page 364: ...350 Ion Classic User Manual...
Page 378: ...364 Ion Classic User Manual...
Page 384: ...370 Ion Classic User Manual...
Page 426: ...412 Ion Classic User Manual...
Page 438: ...424 Ion Classic User Manual...
Page 444: ...430 Ion Classic User Manual...
Page 450: ...436 Ion Classic User Manual...
Page 458: ...444 Ion Classic User Manual...
Page 479: ...Magic Sheets 465...
Page 480: ...466 Ion Classic User Manual...
Page 530: ...516 Ion Classic User Manual...
Page 558: ...544 Ion Classic User Manual...
Page 578: ...564 Ion Classic User Manual...