[At] [Enter] is essentially a “recall from the previous cue” command.
Example:
Cue 5 is active in Live.
•
[Group] [1] [Focus] [At] [Enter]
This command lifts the current move instructions for Group 1 focus, and
recalls the focus data for those lights from the immediately preceding cue. It is
now manual, and can be stored or updated as required.
You may use [At] [Enter] to affect only certain channels or parameters by selecting them
specifically:
•
[2] [At] [Enter] - this will remove the changes for channel 2 only.
•
[2] {Color} [At] [Enter] - this will remove only the color data changes for channel 2.
•
[2] [Thru] [5] [+] [9] [+] [1] [1] [Thru] [1] [5] [-] [1] [2] [-] {Zoom} [At] [Enter] - removes
the changes for only the selected channels for all parameters except zoom.
Modifying Using Record
You may modify a cue by re-recording it entirely. After making changes to channels/
parameters:
•
[Record] [Enter] [Enter] - will replace any data in the active cue with the current stage
settings.
•
[Record] [Cue] [x] [Enter] [Enter] - will replace the any data in cue “x” with the current
stage values.
Using selective storing will modify the existing cue without overwriting it. For more
information, see
Using Selective Store (on page 299)
•
[1] [Record] [Cue] [2] [Enter] [Enter] - will only record the changes to channel 1.
Note:
Using [Record] will store all parameters of all non-default channels onstage.
This means that all other cue data and submaster data will be included in the record
action. This is a common method when working with a single cue list. When working
with multiple cue lists and/ or submasters, [Record Only] is a useful tool.
Modifying Using Record Only
Modifying existing cues using [Record Only] is considered a “selective store” function. As
such, it adds or modifies only manual data to the target cue, but leaves any other data that
was already in the cue intact and does not include playback values from other cue lists or
submasters. [Record Only] is a good way to modify existing cues without including
contributions from other playbacks in the cue. In that way, it is very similar to
.
All of the same commands used for Record may also be used for Record Only.
•
[Record Only] [Enter] [Enter]- adds the current manual data to the selected cue.
•
[Record Only] [Cue] [x] [Enter] [Enter] - adds the current manual data to cue “x”.
[Update]
Update is a powerful feature, and also very versatile. Using a combination of [Q Only], [Track],
[Trace], and {Make Absolute}, the number of ways you can update specific information and
manual data is virtually endless. Data can be updated to various record targets either at once,
or individually.
Summary of Contents for Element Classic
Page 1: ...Ion Classic User Manual Version 3 1 1 4310M1210 3 1 1 RevA 2022 03...
Page 92: ...78 Ion Classic User Manual...
Page 212: ...198 Ion Classic User Manual...
Page 274: ...260 Ion Classic User Manual...
Page 275: ...Mark 261 Chapter 9 Mark About Mark 262 AutoMark 262 Referenced Marks 263...
Page 308: ...294 Ion Classic User Manual...
Page 346: ...332 Ion Classic User Manual...
Page 364: ...350 Ion Classic User Manual...
Page 378: ...364 Ion Classic User Manual...
Page 384: ...370 Ion Classic User Manual...
Page 426: ...412 Ion Classic User Manual...
Page 438: ...424 Ion Classic User Manual...
Page 444: ...430 Ion Classic User Manual...
Page 450: ...436 Ion Classic User Manual...
Page 458: ...444 Ion Classic User Manual...
Page 479: ...Magic Sheets 465...
Page 480: ...466 Ion Classic User Manual...
Page 530: ...516 Ion Classic User Manual...
Page 558: ...544 Ion Classic User Manual...
Page 578: ...564 Ion Classic User Manual...