258
Ion Classic User Manual
About Fan
Fan provides the ability to spread parameter and timing values in a range across a channel
selection set and have those values be evenly spaced. Fan is applied by channel selection or
group order. By default, fan operation is from the start channel.
When {Fan} is pressed after a channel selection, the softkeys will repaint to the following fan
styles:
•
{Center} - The middle channel in the order is set as the start and will remain unchanged,
and the first and last channels will change in different directions. The level wheel will
decrease the lower number channels and increase the higher number channels.
•
{Reverse} - The selected channel order is reversed before applying the fan.
•
{Mirror Out} - The middle channel in the selected order is used as the starting channel
and the first and last channels in the order are the end channels.
•
[1] [Thru] [5] [At] [1][0] [Thru] [3][0] {Fan} {Mirror Out} [Enter] - sets channel 1 to 30%,
2 to 20%, 3 to 10%, 4 to 20%, and 5 to 30%.
•
{Repeat} - The number of channels that are fanned before the pattern is repeated.
•
[1] [Thru] [1][2] [At] [5][0] [Thru] [7][0] {Fan} {Repeat} [3] [Enter] - sets channels 1,4,7,
and 10 at 50%, 2,5,8, and 11 at 60%, and 3,6,9, and 12 at 70%.
•
{Cluster} - The channels are put into collections, which contains channels with all of the
same value.
•
[1] [Thru] [1][2] [At] [5][0] [Thru] [8][0] {Fan} {Cluster} [4] [Enter] - sets channels 1
through 3 at 50%, 4 through 6 at 60%, 7 through 9 at 70%, 10 through 12 at 80%.
•
{Random} - The selected channels are put in a random order before fan is applied.
Fanning Parameter Data
Fan values can be adjusted with either an encoder or via the keypad. To adjust the fan values
with an encoder, select the required channels and provide a baseline, if necessary, followed by
{Fan}.
If no value is entered, the current values will be used. When using encoders to adjust fan, it is
not necessary to specify the parameter to be fanned. This is determined by the encoder used.
•
[1] [Thru] [5] {Fan} [Enter] - selects the channels 1 through 5 and puts encoders and level
wheel into fan mode.
•
[1] [Thru] [5] [At] [5] <0> {Fan} [Enter] - selects the channels 1 through 5, sets a start
level of 50% and puts encoders and level wheel into fan mode.
•
[1] [Thru] [5] {Fan} {Mirror} [Enter] - selects the channels 1 through 5 and puts encoders
and level wheel into fan mode with mirror style.
Fan From the Command Line
A level or time command that uses [Thru] or a list of references is a command line fan
command.
Note:
The {Fan} key is not necessary unless a fan style other than the default is
needed.
To adjust the fan values from the command line:
•
[1] [Thru] [5] [At] [1] <0> [Thru] [5] <0> [Enter] - sets channel 1 to 10%, 2 to 20%, 3 to
30%, 4 to 40%, and 5 to 50%. This is the default fan adjustment and the {Fan}
command is not necessary.
Summary of Contents for Element Classic
Page 1: ...Ion Classic User Manual Version 3 1 1 4310M1210 3 1 1 RevA 2022 03...
Page 92: ...78 Ion Classic User Manual...
Page 212: ...198 Ion Classic User Manual...
Page 274: ...260 Ion Classic User Manual...
Page 275: ...Mark 261 Chapter 9 Mark About Mark 262 AutoMark 262 Referenced Marks 263...
Page 308: ...294 Ion Classic User Manual...
Page 346: ...332 Ion Classic User Manual...
Page 364: ...350 Ion Classic User Manual...
Page 378: ...364 Ion Classic User Manual...
Page 384: ...370 Ion Classic User Manual...
Page 426: ...412 Ion Classic User Manual...
Page 438: ...424 Ion Classic User Manual...
Page 444: ...430 Ion Classic User Manual...
Page 450: ...436 Ion Classic User Manual...
Page 458: ...444 Ion Classic User Manual...
Page 479: ...Magic Sheets 465...
Page 480: ...466 Ion Classic User Manual...
Page 530: ...516 Ion Classic User Manual...
Page 558: ...544 Ion Classic User Manual...
Page 578: ...564 Ion Classic User Manual...