July 2004
4 - 29
4.3.3.14
HAPPY HOUR
See section 4.2.2.7 on the operator interface on
page 8.
4.3.3.15
ENERGY SAVING
See section 4.2.2.8 on the operator interface on
page 8.
4.3.3.16
CLEANING MOMENTS
Press the CLEAN. MMNTS soft key in the main
service menu. The cleaning intervals menu is opened.
See section 4.2.2.9 on the operator interface on
page 9.
In addition to the operator interface options, you can
set the pre-alarm time (due time) in the service menu.
If, for example, the pre-alarm time is set to 120 min-
utes, the operator will be informed to clean the dis-
penser within two hours.
4.3.3.17
TEMPERATURES
Press the TEMPERATURS soft key in the main ser-
vice menu. The temperature menu is opened.
See section 4.2.2.10 on the operator interface on
page 9.
In addition to the operator interface options, you can
make temperature settings. Press the SETTINGS soft
key.
In the following menu, you can determine whether to
block the drink dispensing if the boiler temperature is
too low. You can also set boiler temperatures for
normal operation and for the energy saving mode.
(Fig. 59)
Touch the entry to be modified or use the scroll bar to
switch between the settings. Press the soft keys in the
bottom area of the screen in order to set a selected
entry.
The soft keys in the bottom area change in
accordance with the selected entry (e. g.
DECREASE/INCREASE, NO/YES, etc.).
Fig. 59
NO
YES
TEMPERATURES: SETTINGS
Enable low temperature block:
NO
Boiler temp. (normal)
:
93.0
°
C
Boiler temp. (energy saving) :
63.0
°
C
Cafitesse 700 - Programming
Summary of Contents for Cafitesse 700
Page 4: ......
Page 6: ...July 2004 1 2 Cafitesse 700 Preface and safety instructions ...
Page 12: ...July 2004 1 8 Cafitesse 700 Preface and safety instructions ...
Page 39: ...July 2004 3 1 Table of contents Errors 3 ...
Page 99: ...July 2004 4 36 Cafitesse 700 Programming ...
Page 174: ...July 2004 5A 32 Functions water system Cafitesse 700 Functions water system ...
Page 176: ...July 2004 5B 2 Functions Brewing System Cafitesse 700 Functions Brewing system ...
Page 204: ...July 2004 5F 2 Functions cooling system Cafitesse 700 Functions cooling system ...
Page 232: ...July 2004 5G 8 Functions housing Cafitesse 700 Functions housing ...
Page 252: ......
Page 253: ......
Page 254: ......
Page 255: ......
Page 259: ...July 2004 5L 2 Functions external options Cafitesse 700 Functions external options ...
Page 263: ...July 2004 5P 4 Functions payment systems Cafitesse 700 Functions payment systems ...