5A - 14
Functions - water system
9
10
12
13
•
Pull off the 6-pin plug (9) of the sensor block
(10). (Fig. 3 + 4)
•
Remove the sensor block (10) including the
seal from the cold zone cover (11). (Fig. 3, 4)
•
Pull off the plug contacts (12) on the boil
over sensor (13). (Fig. 4)
•
Remove the boil over sensor (13) from the
cold zone cover. (Fig. 4)
•
The assembly is carried out in reverse order.
•
On assembly, it is important to make sure
that
-
the seal is placed onto the sensor block
from below before both parts are inserted
into the cold zone cover. (Fig. 4)
WARNING:
Make sure to install the correct
boil over sensor for Cafitesse
700 dispensers, which must
not be confused with the one
for Cafitesse 400 dispensers.
Observe the correct activation
temperature of 75
°
C (176
°
F)
±
5 K.
Fig. 4
Fig. 3
9
11
Cafitesse 700 - Functions - water system
Summary of Contents for Cafitesse 700
Page 4: ......
Page 6: ...July 2004 1 2 Cafitesse 700 Preface and safety instructions ...
Page 12: ...July 2004 1 8 Cafitesse 700 Preface and safety instructions ...
Page 39: ...July 2004 3 1 Table of contents Errors 3 ...
Page 99: ...July 2004 4 36 Cafitesse 700 Programming ...
Page 174: ...July 2004 5A 32 Functions water system Cafitesse 700 Functions water system ...
Page 176: ...July 2004 5B 2 Functions Brewing System Cafitesse 700 Functions Brewing system ...
Page 204: ...July 2004 5F 2 Functions cooling system Cafitesse 700 Functions cooling system ...
Page 232: ...July 2004 5G 8 Functions housing Cafitesse 700 Functions housing ...
Page 252: ......
Page 253: ......
Page 254: ......
Page 255: ......
Page 259: ...July 2004 5L 2 Functions external options Cafitesse 700 Functions external options ...
Page 263: ...July 2004 5P 4 Functions payment systems Cafitesse 700 Functions payment systems ...