*errors will be logged
** errors will not be logged
*** UI-error messages: higher priority overrules lower priority, with same priority message of first appearance is shown
July 2004
3 - 10
Errors dosing system
No.
Description
Over-
rules
Set condition
Reset condition
Remarks
Cause
Remedy
Prio-
rity***
40*
Left BIB indicates empty
Empty sensor receives
signal
Automatically, when the
sensor detects that the
BIB is full
(or when the signal is
interrupted).
No automatic
reset, when
EMPTY LOCK
is enabled
1. Float in B2 dosing unit
defective
2. Wiring incorrect or
connections defective
3. Empty sensor
defective
4. PCB B not inserted
correctly in the rack or
defective
1. Replace the product
pack
2. Check wiring or replace
conntections (see
chapter 5K)
3. Replace empty sensor
(see chapter 5F)
4. Insert PCB B correctly or
replace it (see chapter
5K)
55
41*
Middle BIB indicates
empty
Empty sensor receives
signal
Automatically, when the
sensor detects that the
BIB is full
(or when the signal is
interrupted).
No automatic
reset, when
EMPTY LOCK
is enabled
1. Float in B2 dosing unit
defective
2. Wiring incorrect or
connections defective
3. Empty sensor
defective
4. PCB C not inserted
correctly in the rack or
defective
1. Replace the product
pack
2. Check wiring or replace
conntections (see
chapter 5K)
3. Replace empty sensor
(see chapter 5F)
4. Insert PCB C correctly
or replace it (see
chapter 5K)
55
42*
Right BIB indicates
empty
Empty sensor receives
signal
Automatically, when the
sensor detects that the
BIB is full
(or when the signal is
interrupted).
No automatic
reset, when
EMPTY LOCK
is enabled
1. Float in B2 dosing unit
defective
2. Wiring incorrect or
connections defective
3. Empty sensor
defective
4. PCB C not inserted
correctly in the rack or
defective
1. Replace the product
pack
2. Check wiring or replace
conntections (see
chapter 5K)
3. Replace empty sensor
(see chapter 5F)
4. Insert PCB C correctly
or replace it (see
chapter 5K)
55
Summary of Contents for Cafitesse 700
Page 4: ......
Page 6: ...July 2004 1 2 Cafitesse 700 Preface and safety instructions ...
Page 12: ...July 2004 1 8 Cafitesse 700 Preface and safety instructions ...
Page 39: ...July 2004 3 1 Table of contents Errors 3 ...
Page 99: ...July 2004 4 36 Cafitesse 700 Programming ...
Page 174: ...July 2004 5A 32 Functions water system Cafitesse 700 Functions water system ...
Page 176: ...July 2004 5B 2 Functions Brewing System Cafitesse 700 Functions Brewing system ...
Page 204: ...July 2004 5F 2 Functions cooling system Cafitesse 700 Functions cooling system ...
Page 232: ...July 2004 5G 8 Functions housing Cafitesse 700 Functions housing ...
Page 252: ......
Page 253: ......
Page 254: ......
Page 255: ......
Page 259: ...July 2004 5L 2 Functions external options Cafitesse 700 Functions external options ...
Page 263: ...July 2004 5P 4 Functions payment systems Cafitesse 700 Functions payment systems ...