2.7 Technical data
(total overview)
Dimensions:
Version
Version
Version
for cup
for small pot
for large pot
Height:
707 mm/27.8 in
808 mm/31.8 in
915 mm/36.0 in
Width:
692 mm/27.2 in
692 mm/27.2 in
692 mm/27.2 in
Depth:
450 mm/17.7 in
450 mm/17.7 in
450 mm/17.7 in
Height incl. drainage foot:
737 mm/29.0 in
838 mm/33.0 in
945 mm/37.2 in
Height incl. dispenser feet:
752 mm/29.6 in
853 mm/33.6 in
–
Weight:
Version for cup: ~ 62.5 kg/137.8 lbs empty, ~ 84.0 kg/185.2 lbs
filled
Version for pot: ~ 70.5 kg/155.4 lbs empty, ~ 92.0 kg/202.8 lbs
filled
Water connection*:
1/2'’ or 3/8'’ supply line with 3/4'’ BSP connecting piece.
When connecting the dispenser in the U.S.:
Install the dispenser with an adequate return flow stop, which
complies with the local regulations.
Drinking water line with stop valve.
Connection to a hot water supply via copper pipes only.
Supply system requirements:
Water inlet temperature:
max. 75
°
C/167
°
F
Dynamic pressure:
min. 0.8 bar at 10 l/min.
Static pressure:
max. 10 bar
Cold water connection:
Dynamic pressure:
min. 0.8 bar at 1.2 l/min.
for café cool (option)
Static pressure:
max. 7 bar
Boiler filling capacity:
12.5 l/3.3 US gal
Hot water peak capacity:
2.5 l/0.7 gal without internal elbow (standard) + NTC sensor in
low position
6.0 l/1.6 gal with internal elbow (option) + NTC sensor in high
position (USA version standard)
Concentrate capacity:
Packs with a capacity of 2 l/0.53 gal or 1.25 l/0.33 gal (when
using support magnets), containing coffee or milk product,
cocoa-containing beverage and tea product.
Connected load:
For the connected loads, refer to the rating plate. Different
settings can be carried out by the service technician.
Maximum connected loads:
1-phase operation Europe
max. 3.2 kW at AC 230 V / 2.5 kW at AC 200 V
3-phase operation Europe
max. 7.8 kW at AC 3N 400 V
1-phase operation USA max. 1.8 kW at AC 120 V
2-phase operation USA
max. 2.4/3.1 kW at AC 208/240 V / 2.6/3.4 kW at AC 208/240 V
max. 4.2/5.5 kW at AC 208/240 V / 6.4/8.5 kW at AC 208/240 V
Cafitesse 700 - Installation / Puttting into Operation
Summary of Contents for Cafitesse 700
Page 4: ......
Page 6: ...July 2004 1 2 Cafitesse 700 Preface and safety instructions ...
Page 12: ...July 2004 1 8 Cafitesse 700 Preface and safety instructions ...
Page 39: ...July 2004 3 1 Table of contents Errors 3 ...
Page 99: ...July 2004 4 36 Cafitesse 700 Programming ...
Page 174: ...July 2004 5A 32 Functions water system Cafitesse 700 Functions water system ...
Page 176: ...July 2004 5B 2 Functions Brewing System Cafitesse 700 Functions Brewing system ...
Page 204: ...July 2004 5F 2 Functions cooling system Cafitesse 700 Functions cooling system ...
Page 232: ...July 2004 5G 8 Functions housing Cafitesse 700 Functions housing ...
Page 252: ......
Page 253: ......
Page 254: ......
Page 255: ......
Page 259: ...July 2004 5L 2 Functions external options Cafitesse 700 Functions external options ...
Page 263: ...July 2004 5P 4 Functions payment systems Cafitesse 700 Functions payment systems ...