*errors will be logged
** errors will not be logged
*** UI-error messages: higher priority overrules lower priority, with same priority message of first appearance is shown
July 2004
3 - 13
Errors product delivery system
No.
Description
Over-
rules
Set condition
Reset condition
Remarks
Cause
Remedy
Prio-
rity***
60*
Trough and lid is not
(correctly) in place
Trough-in-place-sensor
receives signal
Automatically, when the
sensors detect, that the
trough is in place
1. Trough and lid
incorrectly positioned
2. Wiring incorrect and
connections defective
3. Trough-in-place-
sensor not in the
correct position or
defective
4. PCB C not inserted
correctly in the rack or
defective
1. Position trough and lid
correctly
2. Check wiring or replace
connections (see
chapter 5K)
3. Correct position of
trough-in-place-sensor
or replace it
4. Insert PCB C correctly
or replace it (see
chapter 5K)
110
61*
Left mixer current is out
of spec
Mixer driver circuit has
detected ‚out of spec’ 3
times in a row
Max > 5 A
Min > 0.1 A
After ON/OFF/
CLEAR
switch
This error is
logged and
handled only
after it has
occured 3 times;
relevant drink
selections are
blocked
1. Whipper jammed or
defective
2. Trough assembly
3. Seal defective
4. Mixer motor defective
5. Wiring incorrect or
connections defective
6. PCB B not inserted
correctly in the rack or
defective
1. Replace whipper (see
chapter 5C)
2. Check and correct
trough assembly or
replace trough (see
chapter 5C)
3. Replace seal
4. Replace mixer motor
(see chapter 5C)
5. Check wiring or replace
connections (see
chapter 5K)
6. Insert PCB B correctly or
replace it (see chapter
5K)
100
Summary of Contents for Cafitesse 700
Page 4: ......
Page 6: ...July 2004 1 2 Cafitesse 700 Preface and safety instructions ...
Page 12: ...July 2004 1 8 Cafitesse 700 Preface and safety instructions ...
Page 39: ...July 2004 3 1 Table of contents Errors 3 ...
Page 99: ...July 2004 4 36 Cafitesse 700 Programming ...
Page 174: ...July 2004 5A 32 Functions water system Cafitesse 700 Functions water system ...
Page 176: ...July 2004 5B 2 Functions Brewing System Cafitesse 700 Functions Brewing system ...
Page 204: ...July 2004 5F 2 Functions cooling system Cafitesse 700 Functions cooling system ...
Page 232: ...July 2004 5G 8 Functions housing Cafitesse 700 Functions housing ...
Page 252: ......
Page 253: ......
Page 254: ......
Page 255: ......
Page 259: ...July 2004 5L 2 Functions external options Cafitesse 700 Functions external options ...
Page 263: ...July 2004 5P 4 Functions payment systems Cafitesse 700 Functions payment systems ...