Functions - water system
A.5 Technical specifications
WHAT:
HOW:
Inlet valve
Voltage:
24 V DC
Flow rate:
10 l/min (2.65 gal/min)
Temperature:
90
°
C (194
°
F)
Pressure:
0.8–10 bar
Duty cycle:
100%
Inlet valve with café cool
Voltage:
24 V DC
Pressure:
0–10 bar
Duty cycle:
100 %
Flow rate:
20 cc/sec
Boiler
Pressure:
atmospheric
Capacity:
12.5 l (3.3 gal)
Thermostat:
Temperature:
Tset – 0.3 K
T
set
adjustable via programming
Low temperature indication (
°
F)
Switching-on temperature: T < 60
°
C (140
°
F)
Switching-off temperature: -T=T
set
–4 K
Switching off the heating system via relay
T > T
set
Interrupting the safety circuit via watchdog
T > T
set
+ 5 K
relay
Boil over sensor – activation temperature
T > 75
°
C (167
°
F)
±
5 K
Pumps (kit water tank) (2 pcs. in kit)
Voltage:
12 V DC
Output:
12 l/min
Pressure:
0.5 bar
Outlet valves
Voltage:
24 V DC
Temperature:
98
°
C (208
°
F)
Pressure:
0–60 mbar
Duty cycle:
100 %
Water stop valve
see manufacturer information
Cafitesse 700 - Functions - water system
Summary of Contents for Cafitesse 700
Page 4: ......
Page 6: ...July 2004 1 2 Cafitesse 700 Preface and safety instructions ...
Page 12: ...July 2004 1 8 Cafitesse 700 Preface and safety instructions ...
Page 39: ...July 2004 3 1 Table of contents Errors 3 ...
Page 99: ...July 2004 4 36 Cafitesse 700 Programming ...
Page 174: ...July 2004 5A 32 Functions water system Cafitesse 700 Functions water system ...
Page 176: ...July 2004 5B 2 Functions Brewing System Cafitesse 700 Functions Brewing system ...
Page 204: ...July 2004 5F 2 Functions cooling system Cafitesse 700 Functions cooling system ...
Page 232: ...July 2004 5G 8 Functions housing Cafitesse 700 Functions housing ...
Page 252: ......
Page 253: ......
Page 254: ......
Page 255: ......
Page 259: ...July 2004 5L 2 Functions external options Cafitesse 700 Functions external options ...
Page 263: ...July 2004 5P 4 Functions payment systems Cafitesse 700 Functions payment systems ...