*errors will be logged
** errors will not be logged
*** UI-error messages: higher priority overrules lower priority, with same priority message of first appearance is shown
July 2004
3 - 20
No.
Description
Over-
rules
Set condition
Reset condition
Remarks
Cause
Remedy
Prio-
rity***
88**
All BIBs are empty
85, 86
Software: all the in
CONFIGURATION
installed BIBs are empty.
Automatically when one
of the underlying errors
(40-42) has been cleared
Only shown in
user interface
without error
number
See errors 40-42See errors 40-42
60
89**
No drinks except hot or
cold water are available
Software: multiple
actuators/sensors are
defective
Automatically when at
least one drink except
water can be prepared
Only shown in
user interface
without error
number
See ‘cause’ of active
errors listed in the error
log
See ‚remedy’ of active
errors listed in the error log
68
90*
Data checksum error,
parameter .field 1
(Initial) memory test
failed
After startup of the
dispenser, when the
problem has been
solved.
The memory test of the
MCM detected a memory
failure.
Replace the MCM circuit
board.
210
91*
Flash file system corrupt
After initialization failure
of the MCM flash file
system
Automatically after a
successful initialization of
the flash file system
(after startup of the
dispenser???)
Download via
PC-Service tool
1. Flash file system not
available
2. MCM circuit board
defective
1. Reload the CBX-file via
download file from PC
service tool.
2. Replace MCM circuit
board.
220
92*
Data file missing in flash
file system
When at startup of the
dispenser an invalid data
file (CBX) is found in the
flash file system
After startup of the
dispenser, when the
problem has been
solved.
Download via
PC-Service tool
1. Flash file system is
not available
2. MCM circuit board is
defective.
1. Reload the CBX file via
download file from the
PC service tool
2. Replace the MCM circuit
board.
209
93*
Backup memory failure
Hardware or checksum
error
After startup of the
dispenser, when the
problem has been
solved.
1. Content of backup
flash file is invalid.
2. User interface circuit
board defective
1. Do a BACKUP in the
service menu to reload
the content of the
backup flash file.
2. Replace user interface
circuit board.
204
94
Water valves are not
calibrated
All
Software parameter of at
least one outlet valve is
indicated as ‚not
calibrated’
Automatically when
parameters of all
installed outlet valves
indicate ‚calibrated’
1. Installation sequence
not executed
2. New MCM
3. New data on MCM
1.-3. Calibrate valves
150
Summary of Contents for Cafitesse 700
Page 4: ......
Page 6: ...July 2004 1 2 Cafitesse 700 Preface and safety instructions ...
Page 12: ...July 2004 1 8 Cafitesse 700 Preface and safety instructions ...
Page 39: ...July 2004 3 1 Table of contents Errors 3 ...
Page 99: ...July 2004 4 36 Cafitesse 700 Programming ...
Page 174: ...July 2004 5A 32 Functions water system Cafitesse 700 Functions water system ...
Page 176: ...July 2004 5B 2 Functions Brewing System Cafitesse 700 Functions Brewing system ...
Page 204: ...July 2004 5F 2 Functions cooling system Cafitesse 700 Functions cooling system ...
Page 232: ...July 2004 5G 8 Functions housing Cafitesse 700 Functions housing ...
Page 252: ......
Page 253: ......
Page 254: ......
Page 255: ......
Page 259: ...July 2004 5L 2 Functions external options Cafitesse 700 Functions external options ...
Page 263: ...July 2004 5P 4 Functions payment systems Cafitesse 700 Functions payment systems ...