July 2004
5A - 1
Functions - water system
Outlet valve
Close the adjusting screw on the valve completely. Then un-
screw approx. 3.5–3.75 rotations using an Allen key (wrench size
6 mm).
Calibration via software.
Hot water valve
Close the hot water valve completely and then calibrate it.
Calibration via software, see chapter 4 "Programming".
Water temperature
Adjustable via software, see chapter 4 "Programming".