July 2004
5F - 6
Functions - cooling system
Fig. 2
8
9
10
F.2.3 Disassembly of the fan
Two cooling units with one fan each
are installed in the dispenser.
•
Disconnect the dispenser from the power
supply system and close the water tap.
•
Open the right dispenser door and remove
the locking screw.
•
Remove the left housing cover (1) and the
left front panel (2) and then undo the cable
harness for the delivery button. (Fig. 1)
•
Remove the combined trough (3) and the
water distributor panel (4). (Fig. 1)
•
Take out the water distributor (5). (Fig. 1)
•
Remove the product packs (7) from the
cooling compartment and close the door of
the cooling compartment. (Fig. 1, 2)
•
Press the jack latch downward and then
swivel the cooling compartment (6) upwards
90
°
until the leaf spring on the left latches
into place. (Fig. 1)
Before commencing any disassembly of
the two fans make sure to carry out
the following instructions on both fans.
•
Undo the adapter plug of the cable harness
on the fan.
•
Undo the four screws (8) and remove the
adapter (9) on the fan and the fan (10). (Fig. 3)
•
The assembly of the fans is carried out in
reverse order.
ATTENTION:
When installing the new fans,
it is important to check for the
correct position of installation.
The fan should be mounted
onto the heat sink in centre,
and the air stream directed
toward the heat sink. (The
arrow on the fan point towards
the heat sink.)
To swivel the cooling compartment
downward, slightly press in the leaf
spring. Press the cooling compartment
downward until the jack latch snaps
into place on the bottom left-hand side.
Fig. 3
7
Fig. 1
5
1
2
6
4
3
Cafitesse 700 - Functions - cooling system
Summary of Contents for Cafitesse 700
Page 4: ......
Page 6: ...July 2004 1 2 Cafitesse 700 Preface and safety instructions ...
Page 12: ...July 2004 1 8 Cafitesse 700 Preface and safety instructions ...
Page 39: ...July 2004 3 1 Table of contents Errors 3 ...
Page 99: ...July 2004 4 36 Cafitesse 700 Programming ...
Page 174: ...July 2004 5A 32 Functions water system Cafitesse 700 Functions water system ...
Page 176: ...July 2004 5B 2 Functions Brewing System Cafitesse 700 Functions Brewing system ...
Page 204: ...July 2004 5F 2 Functions cooling system Cafitesse 700 Functions cooling system ...
Page 232: ...July 2004 5G 8 Functions housing Cafitesse 700 Functions housing ...
Page 252: ......
Page 253: ......
Page 254: ......
Page 255: ......
Page 259: ...July 2004 5L 2 Functions external options Cafitesse 700 Functions external options ...
Page 263: ...July 2004 5P 4 Functions payment systems Cafitesse 700 Functions payment systems ...